Category : Recently Uploaded Files
Archive   : GSZ0607.ZIP
Filename : GSZ.DOC

 
Output of file : GSZ.DOC contained in archive : GSZ0607.ZIP




CONTENTS


1. ZMODEM Features at a Glance.................................... 1

2. CUSTOMIZING GSZ................................................ 3
2.1 Setting the GSZ Screen Size............................. 4
2.2 Speeding up GSZ......................................... 4

3. TUTORIAL INTRODUCTION.......................................... 5

4. CALLING GSZ FROM COMM PROGRAMS................................. 6
4.1 USE AN INTERFACE PROGRAM?............................... 6
4.2 MSKermit 3.xx........................................... 6
4.3 PROCOMM PLUS............................................ 7
4.4 Qmodem.................................................. 8
4.5 TELIX................................................... 10

5. BULLETIN BOARD CONSIDERATIONS.................................. 12

6. DESCRIPTION.................................................... 13

7. COMMANDS....................................................... 15
7.1 List of Commands........................................ 15
7.2 Interrupt Keys.......................................... 21

8. NUMERIC PARAMETERS............................................. 22

9. ENVIRONMENT VARIABLES.......................................... 26

10. EXIT STATUS.................................................... 30

11. EXAMPLES....................................................... 31

12. BACKGROUND OPERATION........................................... 32
12.1 Microsoft Windows....................................... 33
12.2 VM...................................................... 34

13. TERMINAL SERVERS............................................... 35
13.0.1 PORT WATCHERS 36

14. FLOW CONTROL................................................... 37

15. ERROR MESSAGES................................................. 38
15.1 Got ZRPOS............................................... 39
15.2 Subpacket too Long...................................... 40
15.3 Bad CRC................................................. 40
15.4 Garbled Data Subpacket.................................. 40
15.5 Serial Input Error: Line Status Register xx ............ 41
15.6 TIMEOUT................................................. 44
15.7 No Carrier Detect....................................... 44








15.8 Port %d (%X) defective.................................. 44
15.9 COMMAND NOT FOUND....................................... 44
15.10 Out of Environment...................................... 45

16. SLOW TRANSFERS................................................. 46

17. IN CASE OF DIFFICULTY.......................................... 47
17.1 LOCKUPS................................................. 47
17.1.1 Insufficient Memory 47
17.1.2 Environment TOO BIG 47
17.1.3 Bad COM Port Configuration 47
17.1.4 LAN Manager Conflicts 48
17.2 Incorrect Batch Files................................... 49
17.3 Cheap Internal Modems................................... 49
17.4 Commands Entered in Upper Case.......................... 49
17.5 No Carrier Detect....................................... 49
17.6 DOS 3.x................................................. 50
17.7 Perstor Controllers..................................... 50
17.8 IBM PS/2 Model 50Z...................................... 50
17.9 Brain Damaged UARTS..................................... 50
17.9.1 Everex Internal Modems 53
17.10 Weird Iron.............................................. 53
17.11 PKARC 3.6............................................... 53
17.12 Will the real YMODEM please stand up?................... 53
17.13 286 and 386 Extended Memory............................. 54
17.14 Disk Caches............................................. 54

18. ASSOCIATED DOCUMENTS........................................... 55

19. FILES.......................................................... 56

20. Other Omen Technology Products................................. 58
20.1 Professional-YAM COMMS TOOLS............................ 58
20.2 ZCOMM: Industrial Strength COMMS Shareware.............. 58
20.3 ZMODEM Developer's Collection........................... 58

21. FAIR PLAY...................................................... 59
21.1 Sharing GSZ Files....................................... 60
21.2 REGISTRATION............................................ 61
21.3 Files on Registration Disk.............................. 63
21.4 Bulletin Board Registration............................. 64

22. CHANGES........................................................ 66

23. ACKNOWLEDGEMENTS............................................... 70















Chuck Forsberg

Omen Technology Inc


ABSTRACT



ZMODEM-90(TM) - Not just another XMODEM hack

GSZ is one of many available programs that implement the ZMODEM file
transfer protocol. GSZ features the ZMODEM-90(TM) extensions including
ZMODEM compression and MobyTurbo(TM) accelerator.

GSZ's ZMODEM provides advanced file management features including two
levels of Intelligent Crash Recovery(TM), and flexible control of
selective file transfers.

The ZMODEM file transfer protocol provides reliable file and command
transfers with complete END-TO-END data integrity between application
programs. GSZ's 32 bit CRC protects against errors that sneak by "error
free" modems and even the most advanced networks.

ZMODEM safeguards all data and supervisory information with effective
error detection. (XMODEM and many recently introduced protocols do not
protect vital supervisory data.)

ZMODEM rapidly transfers files, particularly with modern modems,
timesharing systems, satellite relays, and packet switched networks.
ZMODEM's streaming operation eliminates delays caused by
Kermit/XMODEM/YMODEM/JMODEM block acknowledgements. ZMODEM eliminates
traditional protocols' PACKET LENGTH compromises between transfer
efficiency and error recovery; ZMODEM's packet length is the entire
file.

User Friendliness is an important ZMODEM feature. ZMODEM
AutoDownload(TM) (Automatic file Download without user intervention)
provides a level of convenience unimaginable to users of traditional
protocols.














GSZ - a ZMODEM-90(TM), True YMODEM(TM), XMODEM File Transfer Program


Omen Technology Inc


1. ZMODEM Features at a Glance

_______________________________________________________________________
| Feature | ProCm | RZSZ | DSZ | GSZ | ZCOMM | Pro-YAM |
|________________________|_______|______|______|_____|_______|_________|
|Security Verification | no | no | no | no | no | YES |
|Cybnertic Data Recovery | no | no | YES | YES | YES | YES |
| | | | | | | |
|Command Download | no | YES | no | no | YES | YES |
| | | | | | | |
|Update Directory Tree | no | YES* | no | no | YES | YES |
| Create Directories | no | YES* | no | no | YES | YES |
| Newer files Only | no | YES | YES | YES | YES | YES |
| Protect files | ? | YES | YES | YES | YES | YES |
| Common files Only | no | YES | YES | YES | YES | YES |
| | | | | | | |
|Collision Avoidance | ? | no | YES* | YES | YES | YES |
| | | | | | | |
|Crash Recoverey | YES | YES | YES | YES | YES | YES |
| Verified Accuracy | no | SZ | YES | YES | YES | YES |
| | | | | | | |
|ZMODEM-90(TM) | no | YES | YES | YES | YES | YES |
| Compression | no | YES | YES | YES | YES | YES |
| MobyTurbo(TM) | no | YES* | YES | YES | YES | YES |
| 7-bit Paths OK | no | YES* | YES* | YES | YES | YES |
| | | | | | | |
|OPERATING SYSTEMS | | | | | | |
| Text Translation | no | YES | YES | YES | YES | YES |
| Record Format Support | no | YES | YES | YES | YES | YES |
| DOS Shared Files | ? | - | YES | YES | no | no |
| VMS | no | YES | no | no | no | YES |
| Unix/Xenix | no | YES | no | no | no | YES |
| | | | | | | |
|True YMODEM(TM) | no | YES | YES | YES | YES | YES |
|Demand Upgrade(TM) | no | YES | YES | YES | YES | YES |
|File Transfer Display | YES | no | no | YES | YES | YES |
| TOTAL File Xfer Data | no | YES | YES | YES | YES | YES |
|________________________|_______|______|______|_____|_______|_________|

ProCm = ProComm Plus
* Not available on all flavors or platforms












Chapter 1 Pg 2 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


*************************************************************************
GSZ registration is special.
With most programs, registration only applies only to today's version.
Not GSZ!

GSZ registration bypasses the shareware announcement and unlocks
advanced features in all future versions of GSZ. You don't have to pay
and pay again for new GSZ versions. Omen's Demand Upgrade(TM)
technology allows you to download and activate future GSZ versions
without further registration!
*************************************************************************


DSZ Upgrade!! Include your PAID REGISTRATION DSZ SNP CARD and take
$15.00 off the registration fee!! (The card must be mailed with the
order.) (Be sure to copy your DSZ SNP for safe keeping.)








































Chapter 1 Pg 3 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


2. CUSTOMIZING GSZ

The GCOLORS program customizes GSZ for your environment. GCOLORS
performs the following functions:

+ Customize GSZ's color complement (registration not required).

+ Save and fetch the color selection separately to allow "colorizing"
new copies of GSZ

+ Insert your GSZ serial number and activation key

+ Initialize GSZ with your default communications port (registration
required).[1]

+ Initialize GSZ with your default download directory. (registration
required).

GCOLORS is menu driven and is mostly self explanatory. First GCOLORS
asks for the file name to modify; answer GSZ.EXE.

Sight impaired users can disable the blinking selection pointer by
calling "gcolors -q".

The top menu provides several choices.

Choose colors Modify the GSZ file transfer display color scheme.

Fetched saved colors Fetch the color scheme stored in GCOLORS.T.

adjust for Monochrome display Adjust the color scheme for better
visibility on monochrome displays.

Register Accept your GSZ activation key and insert it in GSZ.

Save changes Save the color scheme in GSZ and GCOLORS.T.

Quit

If your copy of GSZ is registered, two additional choices appear.

set download Directory




__________

1. The default port may be up to 7 characters, so portx definitions may
be used. The validity of the port specification is not checked.






Chapter 2 Pg 4 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


set default Port

Some Color Selection menu choices are not shown on the display:

space increment foreground color

Enter select the next field

F decrement foreground color (f increments)

B decrement background color (b increments)

GCOLORS requires the file GREGDAT.$$$ to serialize GSZ.


2.1 Setting the GSZ Screen Size

Some BBS programs display status information such as the name of the
caller at the bottom of the screen. Normally GSZ clears all 25 screen
lines, but this can be modified with the GSZWINDOW environment
variable:

SET GSZWINDOW=24 protects the 25th line and disables the frame
shadow.

SET GSZWINDOW=23 protects the 24th and 25th lines and disables the
frame and frame shadow.

SET GSZWINDOW=21 Protects lines 22-25, disables the frame, frame
shadow, and the static data GSZ normally shows in
lines 22 and 23.

SET GSZWINDOW=2 Starts the window at line 2. This allows the
calling program to protect information on the top
line. GSZWINDOW values of 3 and 4 also work.
Setting GSZWINDOW does not affect the GSZ t command.

2.2 Speeding up GSZ

GSZ has a V numeric parameter that can be set to 1 to use direct video
I/O for the status display. This speeds up displays but may cause
serial input errors when CGA equipped computers are used at high speeds.

EXAMPLE: GSZ pV1 t

sets direct video output.










Chapter 3 Pg 5 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


3. TUTORIAL INTRODUCTION

If you are just starting out with GSZ, or if you have difficulty getting
GSZ to work, please follow the procedure given below.

Do not run any TSR or other COMM program. This includes LAN programs.
Reboot a clean DOS if necessary.

Start with the following command given directly from the DOS prompt:

gsz port 1 speed 2400 d t

Type it exactly as it appears above; do NOT use upper case.

(Change the port number and speed as necessary. Use only COM1 or COM2
for testing.)

This connects you to the modem. Dial a bulletin board by typing AT
commands to the modem ("ATDT621-3746 ")[1] to make it dial the
BBS. Log in as usual. Then, request a ZMODEM download of a file you
don't already have. The file will download automatically, you don't
have to do anything. This procedure verifies the correct operation of
GSZ.

Next you might try calling the BBS using a higher "baud rate". This
requires setting a higher speed with the "speed" command. A "handshake
on" command may be necessary along with commands to the modem to enable
hardware handshaking in the CTS and RTS leads.

Perhaps you got some error messages before or during the download. The
"ERROR MESSAGES" chapter explains all the commonly seen error messages
and suggests solutions to the underlying problems.











__________

1. If your modem has a non standard setting the ATDT621-3746 command
you type to the modem may not echo on the screen.

If your telephone line requires pulse dialing, use ATDP621-3746 (DP
instead of DT).






Chapter 4 Pg 6 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


4. CALLING GSZ FROM COMM PROGRAMS

If you need to define a trigger string for automatic downloads, make the
program look for "Control-X B 0 0" without the spaces.

It may be necessary to add the DOS command: SET COMSPEC=C:\COMMAND.COM
(change as needed) to your AUTOEXEC.BAT file to allow programs to call
GSZ.

Note: NO SPACES in the SET command!

Please note that gsz reads the hardware to get the speed. The gsz speed
command is hardly ever needed when calling gsz from another program.

4.1 USE AN INTERFACE PROGRAM?

A number of third party programs have been developed to provide a
congenial interface to DSZ if you have enough memory to spare. The
XFER, POE, PCALL, DSZ_ZAP, and PROZ programs have been popular in
interfacing DSZ to ProComm's editor gateway. Many of these support GSZ
as well. These programs are available on many bulletin boards.

Hint: the DOS PATH environment variable must include ProComm's directory
to allow POE to locate all the POE files,. The POE files should be
stored in the ProComm directory. Setting the "PROCOMM" environment
variable is insufficient.


Calling DSZ with these programs requires more memory than calling DSZ
directly.

4.2 MSKermit 3.xx

The "push" command (^[p) in MSKermit 3.xx sends an XOFF character to the
modem before calling DOS. Using this to activate GSZ's term mode with a
"gsz t" command causes most remote hosts to lock up.

The remote host can be unwedged by using the gsz G command, or by
keyboarding XON (Ctrl-Q) from GSZ's terminal mode.

You can add these macros to your MSKERMIT.INI file. Courtesy Keith
Petersen W8SDZ

define sx run gsz F port 2 G sx 1 2,define 1,define 2,
define rz run gsz F ha on port 2 G rz -r
define sz run gsz F ha bo port 2 G sz 1 2,define 1,define 2,
define t run gsz F ha on port 2 G t -r









Chapter 4 Pg 7 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


4.3 PROCOMM PLUS

It's easy to add GSZ to ProComm Plus 2.X.

Datastorm has not licensed ZMODEM-90(TM) technology despite allegations
that DSZ is now "built in" to ProComm Plus version 2. Many users of
ProComm Plus version 2.x use GSZ to get MobyTurbo(TM), Intelligent Crash
Recovery(TM), and other ZMODEM-90(TM) features.

Make sure the GSZ program is in your search path. If you don't see GSZ
announce itself when called from ProComm, GSZ is not in your search
path.

Here are some handy settings for ProComm Plus.

First, you may need to set the DOS environment before running ProComm.
Give these commands to DOS before running ProComm Plus. (These lines
may be added to your AUTOEXEC.BAT file.)

Note: NO SPACES in the SET command!
SET DSZPORT=2 (Only needed for COM2)
SET DSZLOG=GSZ.LOG (Only if you wish a log file)

Then set ProComm's external protocol strings. From terminal mode hit
ALT-S, then select the PROTOCOL OPTIONS menu item.

From that menu select EXTERNAL PROTOCOL OPTIONS. Then set ProComm's
external protocol strings to:
A- External protocol 1 upload filename: ZMODEMU
B- External protocol 1 download filename: ZMODEMD
C- External protocol 2 download filename: ZMODEMMD

The following batch files are included in the GSZ zipfile:
ZMODEMU.BAT (contains: GSZ sz %1 %2 %3 %4 %5 %6 %7 %8 %9)
ZMODEMD.BAT (contains: GSZ rz)
ZMODEMDR.BAT (contains: GSZ rz -r)
ZMODEMMD.BAT (contains: GSZ rz -mr)
ZMODEMAD.BAT (contains: GSZ t)

!!!!IMPORTANT USE lower case (small letters) EXCEPT WHERE SHOWN!!!!


*******************************************************************
Select the ZMODEM PROTOCOL OPTIONS menu and turn off Auto downloading!
*******************************************************************


When sending (uploading) files with ZMODEMU.BAT give the ProComm window
the full pathname (c:/foo/bar/file.ext) for *each* file not residing in
the current directory.






Chapter 4 Pg 8 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


When downloading files with one of the other batch files shown above,
Procomm will also prompt for parameters; just hit ENTER. Or, you can
enter options such as "-mr" if they are't included in the batch file
itself.

Once you've got the hang of things the "ProComm way", try the "gsz t"
command described above to give you automatic ZMODEM-90(TM) downloads
(Look Ma, no keystrokes!!!)..

You can also set the editor hot key (ALT-A) or view program hot key
(ALT-V) by using the ALT-S "FILE/PATH OPTIONS" menu. The strings for
these keys are long enough to store an entire GSZ command line without
need for a batch file.

COM3 and COM4 on Procomm Plus are non standard; in case of difficulty
use COM1 or COM2, or use the portx command.

GSZ may not operate properly when called from ProComm if ProComm has
files open at the time.

A number of reports have been received of problems running GSZ from
ProComm Plus because of insufficient memory. Please refer to the
subchapter on LOCKUPS.

When running under ProComm's Host mode, failure to use the GSZ CON
command may cause ProComm to interfere with file transfers or lock up
the computer.

EXAMPLE: GSZ CON sz %1


Hint: the DOS PATH environment variable must include ProComm's directory
to allow POE to locate all the POE files,. The POE files should be
stored in the ProComm directory. Setting the "PROCOMM" environment
variable is insufficient.


4.4 Qmodem

Changes in the Qmodem interface (arguments passed to the batch file) may
require changes in the batch files shown below, depending on which
version of Qmodem is used.

If you need to define a trigger string for automatic downloads, make the
program look for "Control-X B 0 0" without the spaces.

If you define a protocol with 'Z' as its letter, the latest Qmodem will
detect automatic ZMODEM downloads. Defining an external 'Z' protocol
disables Qmodem's internal ZMODEM, allowing GSZ to be called.

The following is based on a message from Mike Cody, sysop of HomePlate





Chapter 4 Pg 9 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


313-385-9969 3/12/24/96 HST

Go into Qinstall and go to frame 3 Directories. Then select External
protocols #3 I think. Now you will see a definition area to tell Qmodem
the Letter,batchfile combo to use.

Now put Z in the letter definition, Zup.bat in the u/l batch zdown.bat
in the d/l batch, and Y in the batch protocol. Now save it at the menu
with f10 and S.

Then go to DOS and create the following batch files in your Qmodem
directory...

zdown.bat: GSZ port %2 rz -rr

zmdown.bat: GSZ port %2 rz -mrr ((FOR MOBYTURBO!!))

zmdown2.bat: GSZ port %2 est 0 %3 rz -mrr

zup.bat: GSZ port %2 sz %4

!!!!IMPORTANT USE lower case (small letters) EXCEPT WHERE SHOWN!!!!

These are the batch files that will be called by Qmodem. If you did
everything right when you hit PGDN or PGUP you will see an external
protocol called Z) Zmodem in the box. For an easier time do a search for
either External.arc or maybe the string "Qmodem" in the file database as
there is a file with several external protocols and batch files
available in the Mahoney file section (EXEC-PC BBS).

The following batch files for Qmodem are included in the GSZ zipfile:

ZDOWN.BAT contains: GSZ port %2 rz -rr
ZUP.BAT contains: GSZ port %2 sz %4

!!!!IMPORTANT USE lower case (small letters) EXCEPT WHERE SHOWN!!!!

A variation on the receive batch file:
c:elecomqmodem\*y.com ha slow est 0 %3 rz -mrr
A variation on the send batch file:
c:elecomqmodem\*y.com ha cts est 0 %3 sz %4


If Qmodem says "unable to allocate swap space": QMODEM 4.2 will swap all
but approx. 5K to memory or disk when you shell out to GSZ. Go into
QINSTALL and make sure that /O /R Optimum Shell and Disk Shell are both
set to ON.

For older Qmodem versions (before 4.2) change the %4 in upload scripts
to %3.






Chapter 4 Pg 10 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


4.5 TELIX

Telix has an internal ZMODEM, but some users prefer to use GSZ for
performance and/or reliability reasons. Mat Fisher has published a
Telix script to call GSZ for automatic downloads.

For those of you who use GSZ with Telix, here is a sample script
file to use instead of batch files:

//////////////////////////////////////////////////////////////////
//Protocol salt file for Telix's external protocols by Matt Fisher
//Last edited (02/24/90)
//used for the GSZ ZMODEM protocol. (for u/ling & d/ling)
//////////////////////////////////////////////////////////////////

str upload[80] = "c:\telix\DSZ port 1 ha on sz -m -rr ";

str download[80]= "c:\telix\DSZ port 1 ha on rz -b -m -rr ";

//////////////////////////////////////////////////////////////////

Main ()
{
if (_ext_filespec == "")
{ strcat(download,_down_dir); dos(download,0); }
else
{ strcat(upload,_up_dir); strcat(upload,_ext_filespec); dos(upload,0); }
alarm(1);
}
//////////////////////// THE END //////////////////////////////////

Simple but effective...
--- TAGMAIL v2.20
* Origin: CRIMP/John Galt [Node 1] (1:120/144)
INTERNET: [email protected]

NOTE: The DSZ command strings given above are quite unusual. Instead of
the "pW1 ha off" one would be more likely to use "ha on" or "ha sw"
depending on the modem's flow control settings.


From : Bill Logan
Subject : Help With Gsz For Telix

I test and use a variety of terminal programs for individuals.
One of which is telix. I found the script language to be less
than user friendly and installed GSZ via batch files and as an
external protocol. Here are the batch files:

ZMUP.BAT






Chapter 4 Pg 11 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


GSZ pV1 port %2 sz -mr %3

ZMDN.BAT

GSZ pV1 port %2 rz -mrr %3

Then go to ALT O in Telix and insert those batch names in the protocols.

They worked fine for me.

Bill

---
* Origin: PCConsultingAgencyII {=Telecom Node=} (1:300/22)

Use the Telix ALT-O screen to disable Telix's automatic ZMODEM download.








































Chapter 5 Pg 12 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


5. BULLETIN BOARD CONSIDERATIONS

Note to the wise BBS operator: be sure you understand the restrict
command, how and WHY to use it!

When installing GSZ on a bulletin board or host system, be sure to check
for proper operation when the caller hangs up while a file is being sent
or received.

Some bulletin boards do not call GSZ to send a file until they have
verified the file's presence by actually opening the file. If this
checking is done in DOS's default exclusive open mode, gsz's file
sharing will be defeated.

If using a FOSSIL driver, you may need to call DSZ thru a batchfile.
That file should call XU to disable X00 before running DSZ and restart
X00 afterwards. Failure to take this precaution may cause FOSSIL to
steal the COM port from GSZ before file transfers are completed.






































Chapter 6 Pg 13 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


6. DESCRIPTION

GSZ is a "protocol driver" that uses ZMODEM-90(TM), True YMODEM(TM), or
XMODEM to transfer files over a serial port with a variety of programs.

GSZ has two main commands for ZMODEM transfers: "sz" sends file(s), and
"rz" receives them.

When calling bulletin boards to download files with ZMODEM you can avoid
the bother of starting GSZ for each transfer by GSZ's terminal emulator,
before asking the BBS for the download.

gsz t

The "t" command allows you to keyboard the file request directly to the
BBS. (The "t" stands for "terminal emulation".) Just give the "gsz t"
command from DOS or your comms program's DOS GATEWAY. GSZ's ZMODEM
AutoDownload then receives the file automatically, using the filename
provided by the BBS, without any wasted keystrokes or delay. Try it,
you'll like it! (The "t" command is described below.)

YMODEM downloads are almost as easy. Use the "t" command as shown
above, and hit the F3 key after telling the board to download a file
with YMODEM.

ZMODEM and True YMODEM(TM) transfers preserve exact file length and
modification time.

GSZ supports XMODEM-1k (XMODEM with 1024 byte blocks, sometimes
mislabeled as ymodem) and CRC-16 with the sx -k and rc commands.

GSZ is usually called from a communications or bulletin board program.

GSZ uses its own modem I/O. The original interrupt vector, UART parity,
and interrupt configuration are restored on exit. The original state of
the 8259 interrupt mask bit for this vector is also restored on exit.

GSZ uses DOS standard output (stdout) for messages. GSZ never writes
directly to the screen. GSZ expects its standard output to point to the
console, a logging file, or NUL, but never the modem port. If gsz's
standard output is redirected to the modem (as with ProComm's Host mode
DOS shell), the combination will lock up the computer. When necessary,
gsz's standard output can be redirected back to the console device with
the CON command.

DSZ and GSZ automatically support Doorway 2.2 without extra commands.

The RZ.BAT and SZ.BAT files are supplied for convenience when operating
under Doorway. RZ.BAT allows calling programs that emit an "rz" command
to automatically start GSZ from the DOS command prompt. SZ.BAT is a
convenient command interface that complements RZ.BAT. You may modify





Chapter 6 Pg 14 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


SZ.BAT and RZ.BAT with your favorite options.























































Chapter 6 Pg 15 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


7. COMMANDS

***********************************************************
NOTE WELL
Except as noted, all commands and options must be typed in lower case.
DO NOT USE UPPER CASE!!
Case is significant!
***********************************************************

Optional commands or arguments are shown in square brackets [].

When used (in any combination), the A, CON, port, speed, handshake,
estimate, and d commands must be used in exactly this order.

gsz [CON] [F] [port N] [speed S] [handshake XX] [pxN... ] [z pxN... ]
[D] [d] [restrict] [G] command

The shareware program DOORWAY 2.2 interfaces well with DSZ, and provides
many of the same functions, including the ability to run direct screen
writing applications remotely. DSZ and GSZ automatically support
Doorway 2.2 without extra commands.


7.1 List of Commands

CON Redirect message output to the DOS "CON" (console) device,
overriding any previous redirections. This is necessary to avoid
lockups caused by ProComm host mode. Most programs do not require
this hack.

F Leave the 16550A UART FIFO enabled on exit. Since GSZ has no way
to read the 16550A DMA mode and trigger level bits, these values
are not restored.

port N select port N (n = 1,2,3,4,5,6,7,8, or 9) Default is 1 (COM1) or
whatever is read from the DOS DSZPORT dos environment variable.
COM11 to COM18 refer to the COM1 to COM8 ports on the PS/2.

*****************************************************************
NOTE
Only COM1 and COM2 are standard on all PC compatible computers.
Multiple standards exist for COM3 and above, so use only COM1 or
COM2 when first installing GSZ.
*****************************************************************

GSZ COM3 uses 3E8 and IRQ4. GSZ COM4 uses 2E8 and IRQ3.

GSZ COM7 uses 3E8 and IRQ5. GSZ COM8 uses 2E8 and IRQ5.

If you wish to use COM3 or COM4 and your computer is not wired as
shown above, you MUST use the "portx" command to specify the





Chapter 7 Pg 16 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


actual base address and interrupt vector.

EXAMPLE: to use COM2:
gsz port 2 rz

In multitasking operation, accessing a port used by another
running program will hang the machine.


portx base,irq[,divisor] To select an arbitrary port address and
interrupt vector, the portx command must be used instead of the
port command. The portx command replaces the portcommand in the
same place on the command line. Please refer to DSZBG.DOC
(provided on the Registration Diskette) or the Professional-YAM or
ZCOMM (ZCOMMDOC.ZIP) manuals for details on this command.

When the portx command is used, gsz will indicate COM9.

EXAMPLE: gsz portx 3e8,15 speed 19200 handshake on rz

Newer UART chips can use raw bit rate sources up to 8 MHz or more,
more than 4 times as fast as the IBM standard 1.84320 MHz. Some
386 and 486 machines support MobyBaud(TM) operation above 115200
bps. To support a nonstandard bit rate source, multiply 5760 by
the new raw bit rate source frequency in MHz divided by 1.84320.

EXAMPLE: gsz portx 3e8,15,57600 speed 19200 handshake on rz
supports the 18.432 MHz clock option on the Boffin Electronics
"WinSport II" 2 port serial board. Your hardware configuration,
BIOS firmware, operating system, device drivers, and TSR programs
will determine the maximum useful speed.



speed S Set the specified speed. This command is rarely needed because
GSZ reads the port's current speed by default. Please refer to
the FLOW CONTROL, MAIN COMMANDS and SOFTWARE COEXISTENCE chapters
in DSZBG.ZOO or the ZCOMM or Pro-YAM manual for important
information about the speed command.

Please study all the chapters of this document when using speeds
above 2400 bps.

With standard clocking, GSZ supports a maximum speed of 115200.
Not all hardware can support that speed without errors.


handshake XX Enable one of several choices of hardware handshake. (The
default is XOFF/XON software handshake). This command is
documented in the ZCOMM or Pro-YAM manual, and in DSZBG.DOC. (The
ZCOMM manual is available on all bulletin boards registered for





Chapter 7 Pg 17 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


DSZ or GSZ as ZCOMMDOC.ZIP.) On GSZ the "handshake" command may be
abbreviated to "ha".

D Disables the modem (drops Data Terminal Ready, DTR) if carrier is
lost. This may be used to prevent spurious events (phone ringing)
from interfering with the calling bulletin board's recovery from
carrier loss.

d Disables carrier dropout monitoring, for modems that do not
properly drive the "Carrier Detect" input on the PC. If you see a
No Carrier Detect message, you need to give the d command. Before
using the d command, make sure you have the proper port
selected!!!


estimate length [speed] Use the specified length and/or optional
specified effective transfer speed to estimate transfer time for
the next file to be sent or received. The length argument is
mainly used with XMODEM downloads; YMODEM and ZMODEM normally
transfer the file length in the filename packet. The estimate
command must come after any port, speed, or handshake commands.

The estimate command does not affect actual throughput. It only
affects GSZ's prediction of how much time a file transfer will
take.

The following makes GSZ calculate file transfer times based on 290
character per second throughput. Some error correcting 2400 bps
modems can attain this throughput when MobyTurbo(TM) is used.

EXAMPLE: gsz port 2 speed 9600 estimate 0 2900 rz



EXAMPLE: gsz port 2 speed 9600 estimate 0 2900 sz bigmama.zip



pxN Set numeric parameter x to N.

GSZ has two sets of numeric parameters, a base set and a "zmodem"
set. Parameters in the base control such things as date stamping
of files, error exit value, etc. The "zmodem" numeric parameters
control timeouts, window sizes, and other ZMODEM, YMODEM, and
XMODEM protocol parameters.

These parameters are mostly a subset of the Pro-YAM/ZCOMM numeric
parameters, and are listed below. They assume their defaults each
time GSZ is called. Without an argument, p displays the numeric
parameters and their values.






Chapter 7 Pg 18 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


EXAMPLE: gsz p


z pxN Set zmodem numeric parameter x to N. All further numeric
parameter commands are taken as zmodem parameters. The zmodem
numeric parameters correspond to the Pro-YAM or ZCOMM "zmodem"
parameters and rarely need changing. These parameters assume
their defaults each time GSZ is called. Without an argument, z p
displays the zmodem numeric parameters and their values.


restrict Restrict incoming pathnames (YMODEM/ZMODEM) to the current disk
and directory tree, and disallow modification or overwriting of
existing files. This command is vital for bulletin boards
uploading files. The restrict command causes partially received
files to be deleted. When GSZ is restricted, it will refuse to
transfer files containing the string autoexec.bat and command.com
in upper or lower case. This provides some defense from malicious
uploaded files.

EXAMPLE: gsz restrict rz


G Send an XON character to the modem. Useful when calling gsz from
MSKermit to undo the XOFF sent by MSKermit.

EXAMPLE: gsz port 2 G t


t [-T] [-8g] [-h] [-H] Terminal function with ZMODEM AutoDownload.

The optional -T forces GSZ to exit after it has recognized a
ZMODEM AutoDownload(TM) request.

The optional -8g (available on registered copies only) enables
reception of "BBS (ANSI) graphics" displays. (A video device
driver such as ANSI.SYS must be loaded to support some types of
graphics.)

The optional -h enables local echo of keyboarded characters ("half
duplex"). In addition, -H makes the Enter key perform a local
newline (CR/LF).

A small subset of ZCOMM/Pro-YAM term function subcommands are
recognized:

Keyboard F1 or ALT-X to exit.

F3 receives file(s) with True YMODEM(TM),

ALT-P toggles parity between the 8n default and 8g (enables ANSI





Chapter 7 Pg 19 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


"graphics").

ALT-H toggles two local echo ("Half Duplex") modes; the second
displays a newline (CR/LF) when Enter is keyboarded.

Keyboarded ASCII characters are sent to the modem.

ALT-B sends a break.

Characters from the modem print on the screen. A device driver
such as ANSI.SYS may be used to recognize escape sequences.
Standard ANSI.SYS is limited to a small subset of ANSI escape
sequences; NANSI.SYS, FANSI-Console and other replacement console
drivers provide faster screen updates and better ANSI terminal
emulation.

GSZ's ZMODEM AutoDownload(TM) detects the start of a ZMODEM file
download and accepts the file(s) without operator intervention.

rz [-abeEmMnpPrt+YZy] [dir] [file ...] (ZMODEM-90 receive) **

rz [-abenprt+Yy] [dir] [file ...] (ZMODEM receive) **

rb [-abt+y] [dir] [file ...] (YMODEM receive) **


rb -g [-abt+y] [dir] [file ...] (YMODEM-g receive) **

rc [-abt+y] file1 (XMODEM/CRC receive)

ro [-abt+y] file1 (XMODEM OverThruster receive)

rx [-abt+y] file1 (XMODEM receive)

rx -g [-abt+y] file1 (Qmodem-G receive) **

** Download directory specification and -g ignored w/o
registration


sz [-abefnprtFYQS+yZ] [-w[N]] [PREFIX=p | ONAME=n] file ...(ZMODEM
send)

sz [-abeEfmMnpPrtFYQS+yZ] [-w[N]] [PREFIX=p | ONAME=n] file
...(ZMODEM-90 send)

Pathnames are separated by spaces. Wildcards are OK.

EXAMPLE: gsz port 2 sz -r /tmp/file1 /tmp/file3 *.c


The "sz" and "sb" commands exploit DOS's tree structured file





Chapter 7 Pg 20 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


system. A directory or disk specifier expands to all files in
that directory.

EXAMPLE: gsz port 2 sz -r C:srcdir


If you use PREFIX= or ONAME= with the "sb" or "sz" commands, these
pathnames must be entered in lower case unless the underlying file
system supports upper AND lower case.

EXAMPLE: gsz port 2 sz -r ONAME=newsrc.c temp.c



sb [-ft] [PREFIX=p | ONAME=n] file ... (YMODEM or YMODEM-g send)

sb -k [-ft] [PREFIX=p | ONAME=n] file ... (YMODEM-1k or YMODEM-g
send)

sx [-t] file1 (XMODEM, XMODEM/CRC, Qmodem-G send)

sx -k [-t] file1 (XMODEM-1k send)


v Verify the serial number by writing a log entry (see DSZLOG).

v 1 0 bps 0 cps 0 errors 0 128 s/n 666

The letter "v" indicates a verification entry. The first numeric
field is 1 if YMODEM-g is supported. The last field is the serial
number. Unregistered copies show a s/n of 0.


o Turn off Data Terminal Ready (DTR), terminating ("offing") the
connection if the modem responds to DTR. Useful with the "t"
command to disconnect afterwards.

EXAMPLE: gsz t o



LARG Convert ARG to lower case, then parse arg.


The meanings of optional arguments to the file transfer commands are
described in DSZBG.DOC and the ZCOMM/Pro-YAM manual.

The s (SlugBait) option prevents a receiver from receiving a file
without accounting for it. Attempts to do so are flagged with a Q
status in the log file. This option can cause a transfer that
legitimately fails near the end of the file to be reported as





Chapter 7 Pg 21 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


Questionable rather than ERROR. SlugBait causes GSZ to return success
if at least one file is transferred.

Send files may be specified indirectly:
gsz sz @C:files.lst
sends the files in C:files.lst. This provides another means of
bypassing the DOS command line limit. The first letter must be "@" and
the third letter must be ":" to distinguish this from an ordinary
pathname. Pathnames in the indirection file may be separated by any
combination of space(s), tab(s), CR and/or LF. No spaces may appear
inside a pathname; "FOO .BAR" won't work.

A list of files to send may be built up with a command like:

EXAMPLE: dir/w *.zip > files.tmp

This file must be edited to remove extraneous messages and unwanted
files. Then you send the files with:
GSZ sz -m @c:files.tmp


7.2 Interrupt Keys

ALT-B Cancels the current ZMODEM session. Normally this is the best way
to cancel a ZMODEM session.

ALT-F Skips the current file in ZMODEM transfers.

Ctrl-Break Terminates the transfer in progress.

ALT-N Abruptly terminates (NUKES) the transfer in progress.

Ctrl-X If the local program is in its terminal function, typing a dozen
Ctrl-X characters to the remote ZMODEM program terminates ZMODEM
operations with most programs. (Some machines do not allow ZMODEM
programs to check for this.)




















Chapter 8 Pg 22 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


8. NUMERIC PARAMETERS

GSZ uses the following main numeric parameters, settable with the pxN
command.

EXAMPLE: gsz pQ0 rz -rr


**************************************************************************
NOTE: Parameter setting commands such as "pd0" cannot be added to
DSZOPT, they must be included in the command line.
**************************************************************************

In addition, GSZ uses the Pro-YAM/ZCOMM zmodem numeric parameters
described in the Pro-YAM/ZCOMM reference manual (ZCOMMDOC.ZIP) and in
DSZBG.DOC.


B Set the size of buffer used for disk reads and writes. The default
is 1024, 4096 maximum (16384 max on GSZ and DSZ.EXE). If your copy
of GSZ is running on a floppy disk system or a very slow turkey hard
disk, a larger value may give better results. Too large a value may
exhaust memory, induce receiver timeouts, cause disconnects(!), or
generate spurious CRC errors. If performance logging doesn't work,
this parameter is too big.

EXAMPLE: gsz pB4096 sz A:floppy.fil

Setting the buffer size may lock out the performance log, DSZFILES,
and/or indirect pathname list in GSZ.COM.

IF YOU AREN'T BLOODY SURE YOU NEED A BIGGER BUFFER, DON'T USE ONE.

Please understand that the B parameter has nothing to do with
anything you've heard about 128, 1024 or 8192 byte XMODEM style
blocks. Normally, ZMODEM's block size is the entire file!

G This parameter controls the number of bytes loaded into the 16550A
transmit FIFO (First In First Out) storage register on each
interrupt.

For maximum efficiency, GSZ fills the 16 byte transmit FIFO when the
UART generates a FIFO Empty interrupt. Once loaded, data
transmission from the transmit FIFO cannot be stopped, so many bytes
may be sent after the modem sends XOFF or asserts hard flow control
restraint. Good engineering practice requires that modems accept a
large number of bytes after asserting flow control restraint, but
some modems and operating systems won't.

This parameter is effective only with PCDOS machines using FIFO
buffered UART devices. To optimize gsz's responsiveness to flow





Chapter 8 Pg 23 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


control restraint, set this parameter to 0.

EXAMPLE: pG0


O This parameter controls XMODEM OverThruster(TM). It is described in
DSZBG.DOC.

P After a "speed" command, if you give a p command (display
parameters), the P parameter value will indicate the type of serial
I/O UART chip detected. GSZ automatically detects and enables the
FIFO on the NS16550A, NS16550AFN, Goldstar GM82C550, and Intel 82510
chips.

EXAMPLE: gsz port 1 speed 19200 p


0 Indicates a standard 8250 or 16450 UART with no special features.

1 Indicates an NS16550AN or NS16550AFN with 16 deep receive FIFO.
These are the preferred chips.

2 Indicates an Intel 82510 with 3 deep receive FIFO.

3 Indicates a Startech ST16C650 UART with 32 byte FIFOs and on chip
hardware flow control support.

The sequence "port 1 pP1 speed 19200" bypasses GSZ's verification
checks normally performed on the FIFO configuration and may allow
defective FIFO logic on certain chips to be used. This incantation
is not required for the NS16550AN or NS16550AFN.

The sequence "pP-1 speed 2400" should be used with the Western
Digital WD16550 chip to disable the brain damaged FIFO on that chip.
The WD16550 FIFO has been observed to lose data when transmitting at
2400 bps and slower speeds. The minimum speed for normal transmit
FIFO operation with the WD16C550 may vary with different computers.


Q Error code returned to DOS (default 1). (Success always returns 0.)
Some programs toss cookies when confronted with certain exit codes.

EXAMPLE: gsz pQ-1 sz foo.bar


GSZ reports an error if no files have been transferred, even if the
command used wasn't supposed to transfer any file(s).


R If set to 1, causes partially received files to be deleted.






Chapter 8 Pg 24 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


EXAMPLE: GSZ pR1 rz



S Timeout in seconds (default 15) waiting for restraint release (XON
and/or handshake).

V (DSZ.COM and GSZ only) Set this to 1 to use direct to screen video.
This speeds up displays but may cause serial input errors when CGA
equipped computers are used at high speeds.

EXAMPLE: GSZ pV1 rz

sets direct video output.

W Wait for Enter key before exiting after an error. Useful when
calling GSZ from DESQview, allows the window to close unless there
is an error message that should remain visible.

EXAMPLE: gsz pW1 sz foo.bar


Y Control byte for the NS16550AN/NS16550AFN FCR register. If you
don't know what the FCR does, don't mess with this parameter. It
has been suggested that a different value (129) may improve
multitasking under DESQview when multiple copies of GSZ are active.

a Calibrates certain protocol timeouts used with XMODEM and YMODEM
transfers (Cybernetic Data Recovery(TM)). This parameter does not
affect ZMODEM transfers.

The a numeric parameter is automatically set to 2000 for a 4.77 mHz
PC or XT, 4000 for a PS2/30, 6000 for an 8 mHz 1ws AT, and 12000 for
a PS2/80. If your computer has a speedup card or otherwise runs
unusually fast (or slow!) for its type, you may set the a numeric
parameter to a value that reflects its speed.

EXAMPLE: gsz port 2 pa4000 rb


NOTE: Setting this parameter does not suppress the "Unknown Machine
Type" message which is displayed before the command line is scanned.

d A non zero value (the default) causes incoming files received with
ZMODEM and full YMODEM transfers to have their Date set to that sent
in the file header. ZMODEM's file management features depend on the
transmission of each file's modification date. Files will have the
same creation date, even if the two machines are in different time
zones. When transferring files to/from a Unix system, creation
dates are interpreted according to GMT or Universal Coordinated
Time. File dating may be disabled with a pd0 command, which causes





Chapter 8 Pg 25 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


files to assume the date and time they were received.
NOTE: Backdating file creation times may confuse some backup
programs.

v Verbose level (debugging output) Negative values inhibit some
routine messages. Setting v to 1 or greater causes serialized
copies to ring the bell when a transfer is done.

EXAMPLE: gsz port 2 pv1 rz


z Timezone in minutes behind GMT, used for ZMODEM and True YMODEM file
transfers to coordinate the actual date of the file with computers
in other time zones. PDT or MST corresponds to 420. This may be
preset with the ZONE DOS environment variable.










































Chapter 9 Pg 26 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


9. ENVIRONMENT VARIABLES

The following DOS environment variables may be set to modify GSZ
operation. DOS environment variables are set by giving a command to DOS
before running GSZ. You can add these commands to your autoexec.bat
file.


EXAMPLE: set DSZPORT=2


The following form may be used for arbitrary address/vector
combinations:

EXAMPLE: set DSZPORT=3e8,4

These DOS "set" commands may be placed in your AUTOEXEC.BAT file or
given just before you run your communications program.

IMPORTANT! Do not add spaces to these commands!!
set DSZPORT = 2 WILL NOT WORK!


DIRRX (Registered copies only.) Specifies the directory to receive
(download) files. If the sting in DIRRX ends with "/", directory
and/or disk designators in the incoming pathname are stripped, and
only the stem (name and extension) is used. Otherwise, if an
incoming file has an absolute pathname, the incoming pathname is
used.

EXAMPLE: set DIRRX=C:/modem/download/gsz/
gsz rz -r
downloads files to the /modem/download/gsz directory on the C:
drive, with ZMODEM Crash Recovery..


EXAMPLE: set DIRRX=B:/

The DOS "set" command defining the receive directory may be placed
in your AUTOEXEC.BAT file. Make certain there is enough environment
space to hold this value. Confirm this by typing "set" to the DOS
prompt and verifying the DIRRX value is listed correctly.

DSZFILES May contain a list of up to 9999 pathnames to transmit, with
entries separated by spaces. If present, DSZFILES is used in place
of a normal command line list of files to send with the sb and sz
commands.

EXAMPLE: set DSZFILES=file1 file2 file3 *.c
gsz port 2 handshake on sz -rr






Chapter 9 Pg 27 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


In practice, this string would be built up by a calling program and
passed to GSZ with a "spawnvpe", "execvpe", or similar subroutine
call.

SEE ALSO: Pathname list specification @C:files.lst

DSZLOG log file to receive entries for files sent and received.
(Default null). Sample entries:

Z 46532 38400 bps 3324 cps 0 errors 66 1024 GSZ.COM 1177
Z 124087 19200 bps 1880 cps 0 errors 6 1024 MXY.TMP 1177

Transfer times are based on the DOS time of day clock and have up to
two seconds' uncertainty. As with all protocol throughput reports
generated by Omen Technology programs (and contrary to the false
claims of some critics), GSZ's throughput figures for ZMODEM,
Kermit, and True YMODEM(TM) transfers do not take "credit" for
pathname and/or protocol overhead characters. GSZ's throughput
reports do not include the time required to send the pathname. This
understates the true time required to transfer files, but the time
required to send the pathname often depends on the alacrity of the
operator, and thus does not always reflect the performance of the
protocol itself.

Transfers measuring less than one second are reported as having 9999
characters per second throughput.

The unlabeled numeric field after the error (retry) count is the
number of flow control stoppages encountered sending the file. Flow
control restrictions are normal when the interface speed exceeds the
communications speed (DTE > DCE). This number gives an indication
of flow control restrictions (overloaded networks, etc.) encountered
during the transfer.

The last numeric field before the file name is the YMODEM block size
or ZMODEM subpacket length used for the last block in the file.

The last field is the serial number of the other program, or -1 if
this information is not available. When sending files, the
receiving program's serial number is not normally available unless
the -S option is used.

The code letter indicates the type of transfer, Z (ZMODEM), S
(X/YMODEM), R (X/YMODEM), E (error), or L (transfer terminated by
loss of data carrier).

WARNING: If GSZ encounters a loss of carrier or other fatal error
condition before a file COMMENCES transmission, a log entry may not
be made.







Chapter 9 Pg 28 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


EXAMPLE: set DSZLOG=C:/yam/gszlog


IMPORTANT! NO SPACES!!


DSZOPT (Registered copies only) String containing default options for
GSZ file transfers. Legal option letters for DSZOPT are the
optional modifiers to the GSZ sz, rz, sx, rx, sb, rb commands.

A T may be appended to the string to force GSZ to exit after it has
recognized a ZMODEM AutoDownload(TM) request.

An 8g may be appended to the string to make BBS (ANSI) graphics the
default for GSZ's t command. The ability to preset these options is
especially helpful for controlling ZMODEM automatic downloads from
GSZ's t command.

EXAMPLE: set DSZOPT=r
Enables GSZ's Intelligent Crash Recovery(TM) as a default.

Let's say you wish ZMODEM crash recovery, and BBS "graphics" for the
GSZ term function:
set DSZOPT=r8g


If you're downloading files from GEnie with an MNP modem, the
following will speed up your downloads with Genie's ZMODEM-90Tm.
(You can recognize ZMODEM-90 on GEnie two ways: 1) MobyTurboTm is
used to speed ZIP and ARC downloads, 2) "sz 4.xx" is displayed at
the end of transfer. As of this writing, ZMODEM-90 may not be
available in all libraries.) Note that (as usual with GSZ) case is
significant: the "r" must be lower case, the "W" upper case.
set DSZOPT=rW16384


WARNING: Do NOT include "ena" or any other commands in the DSZOPT
string. With the exception of the "8g" mode, only **options** may
be placed in the DSZOPT string! (Options are the letters that
modify the sz, rz, sb, etc. commands. In "rz -r", "r" is an
option.)

Parameters can not be set in DSZOPT.

MAXBYTES Maximum number of bytes allowed for transfer. If this number
is exceeded, GSZ skips the offending files (ZMODEM) or aborts
remaining files in the batch (YMODEM).

DSZPORT Default communications port override, default 1.

EXAMPLE: set DSZPORT=2





Chapter 9 Pg 29 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


IMPORTANT! NO SPACES!!



ZONE sets the z numeric parameter to the number of minutes the current
local time lags GMT time. PDT or MST corresponds to 420. PST
corresponds to 480.
EXAMPLE:
set ZONE=420















































Chapter 10 Pg 30 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


10. EXIT STATUS

GSZ exits with 0 status for successful transfers or the value of the Q
numeric parameter (default 1) if a file transfer failed, or if no files
were transferred. Many languages and "door" programs do not return this
information to the calling program. Some languages and "door" programs
freak out (hang) on certain non-zero exit values.

A batch file that calls GSZ directly may be used to detect the GSZ exit
status with the DOS "errorlevel" construct. Please refer to the Q
numeric parameter below for more information.

GSZ's log file entries may also be examined to determine the success or
failure of a file transfer.

GSZ commands are an improper subset of Pro-YAM/PowerCom/ZCOMM commands.
The file transfer commands are fully described in ZCOMMDOC.ZIP, the
ZCOMM User's Manual. (ZCOMM is a full featured shareware communications
program with autodialing, autolearn scripting, and terminal emulation.)
Portions of the ZCOMM User's Manual are also provided in DSZBG.ZOO. You
may refer to one of those documents for details on the following
commands.


































Chapter 11 Pg 31 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


11. EXAMPLES

gsz sz c:foo.zip (send 1 file with ZMODEM)

gsz sz -m c:*.zip (send all .ZIP files with MobyTurbo(TM))

gsz sz f1.c f2.c f3.c (send 3 files with ZMODEM)

gsz sz c:foo.* b:*.c (send multiple files with ZMODEM)

gsz sz -Z *.lst (send text files with ZMODEM compression)

gsz sz -r bigone.zip (CRASH RECOVERY: resume interrupted
transfer)

gsz rz -r (CRASH RECOVERY: resume interrupted
transfer)

gsz rz -rr (CRASH RECOVERY with file comparison)

gsz handshake both sz yamdemo.zip (Hardware+Software handshake)

gsz sz -n *.* (send files that are newer or rx has no
copy)

gsz sz -Yn *.* (Only send files that are newer than
receiver's copy)
(Do not send files that do not exist on
receiver's disk)

gsz rz C:/UPLOADS (receive files to specified directory *)

gsz port 2 speed 38400 handshake both restrict rz
(Restrict provides protection for BBS's)

gsz rz -y prog.zip (ZMODEM, single file pathname override)

gsz pR1 rx foo.dat (XMODEM receive, remove file if error)

gsz pO60 ro foo.dat (XMODEM/OverThruster receive, GEnie MNP *)

GSZ LRC L-Y NEWPROG.ZIP (generate lower case "rc -y" command)

gsz sz foo >debug.dmp (Debugging data dump)

gsz sz @C:/bbs/files.lst (Indirect file list)

gsz sz -u *.lst (Unlink (Delete) files as they are sent)

* Registered copies only






Chapter 11 Pg 32 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


12. BACKGROUND OPERATION

Three DESQview description files are provided to demonstrate background
operation with modest (66 kb window) memory requirements. DSZ uses
tight C/ASM code, table driven CRC generators, and buffered receive and
transmit for good performance in the background without hogging CPU
cycles. On a QIC Labs 8 mHz PC-AT clone, DSZ can download files in the
background (3 background clock ticks, 9 foreground clock ticks) with a
throughput better than 9600 bps.

GSZ operates under DESQview with 128k of memory.

HINT: make sure "Separate Shift State" is set to "N".

2S Prompts for file name(s) and sends them with ZMODEM protocol.
File: 2S-PIF.DVP

2T Talks to the modem and allows manual YMODEM (F3) or automatic
ZMODEM downloads. File: 2T-PIF.DVP

2A Like 2T, but using Quarterdeck's dvansi.com memory resident ANSI
CRT device driver to process ANSI screen codes. File: 2A-PIF.DVP
DS.BAT is the batch file used by 2A.

These files are written for a port 2 local connection and \TMP
directory, but may be modified to suit your requirements using the
DESQview CP command. The W numeric allows DESQview to close the window
after DSZ finishes, providing a pleasant user interface.

Other DVPs, Scripts, and Batch files are available on the DESQView
conference on the Sound of Music as DVDSZ20Z.ARC.

Please consult the DESQview documentation for instructions on
installation procedure for the DVP files.

Operation at high speed (above 9600 bps) may require the DESQview
"Optimize communications" performance Advanced Setup option.

Newer versions of DESQview may require more "common memory" allocation
(6-8 k bytes) to operate with DSZ. Some versions of DESQview do not
operate properly with DSZ; DESQview 2.0 is known to work, and DESQview
2.25 is reported to have fixed bugs in intermediate versions.

On 286 and 386 machines, some DESQview operations involve swapping
memory contents with buffers in extended memory. As with extended
memory ramdisks and disk caches, this causes errors with high speed
communications. The considerations discussed in the "286 and 386
Extended Memory" subchapter apply here. Since this DESQview extended
memory swapping is asynchronous with respect to DSZ's file transfers,
"handshake slow" doesn't help here. The solution is to force DESQview's
memory swaps to use smaller blocks (with interrupts allowed between





Chapter 12 Pg 33 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


blocks) and/or use NS16550AN or NS16550AFN or Goldstar GM82C550 chips
for the serial interface.

If you see funny characters on the screen while a program is loading,
you have a conflict between the display adapter and QEMM memory manager
which may cause lockups. If so you must explicitly exclude the display
adapter's memory with an EXCLUDE clause in QEMM's config.sys entry.

***********************************************************
WARNING
When running GSZ under a multi tasking system such as DESQview, do not
allow two programs to access the same comm port at the same time. At
best, such actions will disrupt communications. At worst, your computer
will attempt to open a subspace channel to V'ger.

Tell DESQview to use the SPECIFIC port number you are using, and not "Y"
to the question: "Uses serial Ports (Y, N, 1, 2)"

When running a comm program under DESQview or any related multitasking
executive, GSZ must be called directly from the comm program, in the
same window. DO NOT open a separate window for DSZ unless you were
about to power down the computer anyway.
***********************************************************

With some communications programs, you can make the call, log in, and
then exit (closing the window) without disconnecting the modem. At this
time you can fire up DSZ with the "t" command to allow YMODEM or ZMODEM
downloads in a small window.
Example File: 2A-PIF.DVP

Alternatively, you can start DSZ from the DOS prompt, then type "AT"
commands to the modem to call the bulletin board. DESQview's "learn"
facility may be helpful here.

12.1 Microsoft Windows

Communications programs do not operate well under Windows 3 because
Windows does not support true multitasking. The severity of this
interference depends on the version of Windows and what other programs
are active or loading.

First, uprade to Windows 3.11 or use one of the aftermarket replacement
for the windows comm driver.

You MUST use a 16550A FIFO UART if you are using windows, even if runs
just fine under DOS with a plain UART.

Set and the modem to use hardware flow control.

Add the following lines to your system.ini file in the [386enh] section,
where n is replaced by the COMn digit:





Chapter 12 Pg 34 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


MinTimeslice=20
WinTimeslice=100,50
COMnFIFO=1
COMnBuffer=4096


For best results when running in the MS-DOS shell, try the "Exclusive"
and "Background" items in the "Settings" menu. Also, bring up the
"Control Panel" "386 Enhanced" menu, and set the "Minimum Timeslice" to
a smaller values such as 2.

OS/2 and Chicago provide better multitasking than Windows 3.1.

12.2 VM

According to Marshall Sutherland, Be sure to set IOPL3 mode to YES.








































Chapter 13 Pg 35 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


13. TERMINAL SERVERS

Often users must use terminal servers or multiplexers to access Unix,
VMS, and other timesharing systems. Terminals on some timesharing
systems are connected indirectly to the host with TERMINAL SERVERS
operating over networks. Terminal servers often interfere with file
transfers by "eating" control characters and/or losing data.

Accessing a distant system using telnet on a local Unix system entails
the same problems. If telnet does not work well, try rlogin with the -8
option. Set the escape character to ^P (control P) which is protected
by ZMODEM.

When terminal servers interfere with file transfers, server commands are
often available to help the problem. When possible, enable the server
and modems for hardware flow control in and out. Set the terminal
server to telnet transparent mode. Some typical commands are "SET
TERMINAL DOWNLOAD", "set session passall", and "SET TERMINAL NO ESC",
but there is no standard set of commands suitable for all terminal
servers. Normally these commands are given before attempting file
transfers, but one user has reported that the command must be given
after the file transfer is started(!). Until terminal server vendors
improve the quality of their product, you may have to get on their case
until they adequately support high performance file transfers.

Escaping control characters with ZMODEM (sz -e) may help if the transfer
gets stuck in the same place on every attempt. Professional-YAM and
ZCOMM allow selection of which control characters need to be escaped.
In extreme cases 7-bit transmission may be required (see the
Professional-YAM/ZCOMM manual). If you encounter problems with control
characters you should identify which control characters are causing the
problem. Please refer to the sz -T command in sz.doc for more help.

Flow control between the server and modem is often defective. This
rarely causes a problem in interactive applications whose short bursts
(a screenfull at most) fit within the available memory buffers.
Streaming protocols such as YMODEM-g, long packet SuperKermit, and
ZMODEM can overload the available buffering. Some terminal servers
support commands to enable hardware flow control such as "TERM
FLOWCONTROL HARDWARE IN OUT"; this assumes the modem attached to the
server is properly configured.

If the terminal server is too brain damaged to support flow control,
ZMODEM lets you fake it by setting a window size. Try
sz -w2048 file...
to enable software flow control. Experiment with different window sizes
for best results.

Terminal servers are designed to accept keyboard input from human
operators. They may lose data when a program sends more data to the
host faster than humans type. Some servers allow larger input buffers





Chapter 13 Pg 36 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


to support file uploads. If you can upload short files (less than 100
bytes) but not longer files, try
sz -w1024 file...
with your uploading program. (Not all programs support this option; use
ZCOMM or Professional-YAM.)

When both flow control and character transparency are problems, use
sz -ew1024 file...
as a starting point.

Sometimes the terminal server software is defective and must be
corrected. Please contact the network's vendor for corrective
procedures. An alternative is to install direct serial ports for users
desiring to upload files.

We have also encountered problems when networking software fails to pass
data after a large amount of data has been sent to the host. This has
happened on a PPP internet connection which prevented uploads of large
amounts of data via either FTP or a ZMODEM upload (via TELNET). The PPP
connection grinds to a standstill and not even PING works. The same
ZMODEM/TELNET combination easily uploaded ten times as much to a nearby
machine connected by Ethernet.


13.0.1 PORT WATCHERS
Some systems enforce a timeout which disconnects a user after several
minutes of keyboard inactivity. Long, error free ZMODEM transfers do
not generate keyboard activity (this is why ZMODEM is so efficient).
Restricting the window size with
sz -w16384 file...
option generates terminal input at regular intervals even when no error
correction is needed. If problems persist, try setting a packet length.
sz -l1024 file...
(The default ZMODEM packet length is the file length.)






















Chapter 14 Pg 37 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


14. FLOW CONTROL

If you plan to send files over Telenet (PC-Pursuit), you must refer to
the Pro-YAM or ZCOMM Reference manual (in ZCOMMDOC.ZIP) FLOW CONTROL
chapter for vital information on flow control considerations necessary
for proper operation of ZMODEM and other streaming protocols. (ZCOMM is
a full featured shareware communications program with autodialing,
autolearn scripting, and terminal emulation.)

















































Chapter 15 Pg 38 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


15. ERROR MESSAGES

COM2 1200 bps Carrier Detect enabled Handshake slow
Command line = (commands)
This is a normal message displayed to help resolve problems with
incorrect batch files. The port number, speed, carrier detect
("enabled" or "DISABLED") and "handshake" indicate the selected mode of
operation.

GSZ FINISHED! exit code = 0
This is GSZ's normal exit when at least one file has been transferred
and no unrecoverable errors have been detected. If an error such as a
failed file transfer had been detected, the exit code would be 1, or the
value set in the Q numeric parameter.

As the message implies, GSZ has done all of its processing, and has
return the communications port and vector to its original value before
displaying this message. If the computer locks up after this message is
displayed, there's something wrong with the program that called GSZ, not
with GSZ itself.

Unknown Machine Type XX, 'a' parameter preset to 6000 indicates a ROM
BIOS that does not follow the IBM specification for identifying the
machine type. If your computer causes GSZ to display this message, you
may set the a numeric parameter described elsewhere in this document.
This message is generated before any commands are read, so do not be
alarmed when you "discover" that setting the a parameter doesn't make
this message go away. The a parameter does not affect ZMODEM transfers.

Please send us a postcard or letter indicating the reported hex value
for machine Type, name of the computer, and its speed so we can include
that machine type in a future release.

Need more memory to run GSZ or Abnormal program termination is displayed
by the TurboC startup routine if GSZ is run in too small a memory
partition. If you see this message, use a larger memory partition for
GSZ or remove some memory resident programs. This message may also
appear if the calling program fails to free memory before calling GSZ.

No Carrier Detect is displayed when GSZ recognizes a lack of carrier
detect signal from the modem. Most support calls concerning "No Carrier
Detect" are caused by the user failing to tell GSZ to use the correct
port. GSZ does not magically divine the COM port number; if the default
COM1 is incorrect, GSZ must be told what port to use with the port
command or the DPORT environment variable.

The No Carrier Detect message may also be caused by a line disconnect,
defective cable, or incorrect modem strapping. Sometimes this is caused
by setting the B parameter to too large a value.

The No Carrier Detect message may be disabled with the d command. The d





Chapter 15 Pg 39 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


command must be given after any port or speed commands.

Garbage Count Exceeded Indicates ZMODEM has not detected a valid start
of header in a reasonable number of characters.

If GSZ becomes "stuck" on emitting this messages, it is possible the
sending program may not be able to recognize and act upon transmission
requests (ZROPS headers). The sending program should be corrected. In
the meantime, setting a ZMODEM packet length with the "zmodem pl4096"
("l" is the small letter l) command will force the sender to wait for
the receivers' progress reports.

Permission denied comes from the Microsoft C Library. This is caused by
attempts to modify a read only file or directory, or to create a file in
a nonexistent directory.

Appearance of XOFF or FLOW during ZMODEM or YMODEM-g file sending
signifies GSZ is responding to flow control restraint. This is normal
operation when error correcting modems or packet switched networks are
used. ZMODEM's robustness and reliability allow creative users to
transfer files over unusual multiple hop computer lash-ups, causing
modem data lights and computer status displays to dance in unfamiliar
rhythms.

Output FLow Control Restraint RELEASED Indcates GSZ has not received a
positive flow control signal (XON and/or CTS as specified by the
handshake command) within the timeout specified by the S numeric
parameter. This message may appear as the result of line noise. If it
appears often, it may indicate improper flow control settings, defective
modem and/or cable, or (rarely) too small a value for the S numeric
parameter. A TSR program that monitors ring detect has also caused this
problem.

Not allowed to overwrite file.ext By default, GSZ will not overwrite an
existing file. Use the -y or -n or -r option to overwrite/update
existing files.


15.1 Got ZRPOS

Got ZRPOS indicates the receiving program has detected a transmission
error and has requested retransmission. In other words, ZMODEM is doing
its job of detecting and correcting missing and garbled data.

If this happens with error correcting modems, or more often than
observed line noise would suggest, the receiver's error messages must be
studied. "Line Status Register 01" messages indicate a flow control
problem. "Line Status Register 02" messages suggest a receiver problem
with interrupt latency.

Otherwise, the sender may have a flow control problem in one of four





Chapter 15 Pg 40 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


areas:

+ Between the sending program and its modem. If using an interface
speed higher than the transmission speed, or modem to modem error
correction (MNP, LAPB, PEP, etc.), check that the modem and the
sending program are configured for the same flow control methods.
Omen Technology's software is faster than most other programs, and
may expose flow control problems not seen with slower software.

+ Between the sending modem and the network. Correcting this requires
"handshake both" to allow the sending program to honor both hardware
(CTS) flow control from the modem and software flow control
(XON/XOFF) from the network.

+ Between parts of the network, or between the host computer and its
terminal server(s). We have received a number of reports of
problems with Cisco terminal servers.

+ Between the receiving modem and the receiving program. This can
happen at high transmission speeds when the receiver has specified a
large I/O buffer size with the B numeric parameter.

Excessive interrupt latency from extended memory ramdisks or disk
caches, and poorly written hard disk drivers also wreak havoc on
streaming protocols but do not affect start-stop protocols (XMODEM,
etc.). Problems with extended memory disk caches may cause errors
at regular intervals; check the receiver's error messages.

To work around these problems, give the "handshake slow" command to
the receiver.


15.2 Subpacket too Long

This error is often caused by flow control problems at the sender (see
above).


15.3 Bad CRC

This error is often caused by flow control problems at the sender (see
above). If an odd Length is routinely reported, the cause is almost
certainly incorrectly configured flow control at the sending end.


15.4 Garbled Data Subpacket

This error may be caused by flow control problems at the sender (see
above).

Byte NNNN retry M: These messages appear when the





Chapter 15 Pg 41 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


protocol has detected an error and is attempting to retransmit the
garbled data. These are normal messages.


15.5 Serial Input Error: Line Status Register xx

Serial Input Error: Line Status Register HH indicates a hardware
problem, slow device driver, TSR program, or other software is disabling
interrupts too long for the program to accept incoming data, and some
characters are lost. A slow response to flow control also triggers this
message.

The value of the line status register is displayed in HEX. The
following error conditions are OR'ed into the Line Status Register.


01 The Interrupt level circular buffer has been overrun. This
indicates a flow control problem. The remote did not respond to
GSZ's XOFF or hardware flow control signal, and continued to send
characters after being told not to. This problem is alleviated by
matching flow control between the sending computer, modems, and the
receiving computer. Usually, the mismatch exists between the
sending computer and its modem.


02 An 02 value (or any even number) for the LSR indicates Data
Overrun. "Data Overrun" means the computer was not able to respond
to an incoming character from the UART (modem) in time to make room
for the next incoming character. Data Overruns are caused by
poorly designed software and/or ROM BIOS "firmware" locking out
interrupts for excessive periods. These lockouts increase the
interrupt latency, the amount of time which transpires between the
arrival of an interrupt from the modem and transfer of control to
the interrupt service routines that read the modem data to memory.
These lockouts prevent communications routines from responding to
the incoming characters in time to prevent data loss.

Other chapters in this document give suggestions for working around
excessive interrupt latency by using the NS16550AN or other
buffered UART chips. Please refer to the "Brain Damaged UARTS"
subchapter.

Please try all the suggestions mentioned here before contacting
Omen Technology about data overruns.

Common causes of excessively long interrupt lockouts ("critical
code regions") are mouse drivers, disk drivers (BIOS), EIDE disk
block transfers, window managers (Windows 3 is terrible), disk
cache programs including Microsoft SMARTDRV, TSR programs, and
EGA/VGA board auto-select.






Chapter 15 Pg 42 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


Slowing the CPU to allow games and other time dependent programs to
be used can generate excessive interrupt latency.

Some BIOS routines are written without regard to their effect on
high speed communications. Better versions of the offending BIOS
ROMS may be made available if enough users complain about poor
performance. In some cases disabling "multiple block transfer" in
the BIOS improves communications.

Interrupt latency caused by EIDE block transfers can be reduced by
disabling EIDE block transfers.

Interrupt latency caused by EGA/VGA board auto-select can be often
corrected by disabling the board's Auto-Select.

Device drivers and TSRs loaded in high memory sometimes cause
interrupt latency problems that can be corrected by moving them
into low memory.

Poorly written disk caches and disk drivers cause interrupt latency
that affects protocols. Some disk cache programs can be set to
cache disk reads only, avoiding the massive delayed writes that
interfere with file downloads. With Microsoft SMARTDRV.EXE, try
using the /E option.

Mouse drivers have been reported to cause loss of serial data. If
mouse movements interfere with file transfers, do not move the
mouse when transferrng files.

To correct Data Overruns, you must correct the offending
condition(s) to allow the communications program to operate
properly.

The handshake slow command can be used to stop reception during
disk transfers. However, handshake slow is not always an effective
alternative to correcting the real problem. When using the
handshake slow command, experiment with locking the modem to
different speeds. Sometimes a higher speed actually works better.

The zmodem k numeric parameter can be set to flush the SMARTDRV
cache under controlled conditions. This may be used to reduce
errors caused by SMARTDRV. When used with SMARTDEV, set the zmodem
k numeric parameter to the number of kilobytes the should be
received before flushing SMARTDRV. This number should be low
enough to flush SMARTDRV before SMARTDRV periodically flushes
itself.


Downloading files temporarily to a RAMDISK may help. Files on the
RAMDISK must be copied to a real disk before they are safely
stored.





Chapter 15 Pg 43 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


!=2 With DOS flavors of one can select a 16384 buffer size, you
may be able to avoid problems receiving by using a large i/o buffer
and forcing ZMODEM to stop when this buffer fills:
pI16384 z pl16384
or
pI16384 z pk1

If the I numeric parameter is non zero, it controls how often
SMARTDRV is flushed if the zmodem k parameter is non zero. A CASE
STUDY: NEC UltraLite VERSA The NEC UltraLite VERSA provides a case
study of how brain damaged hardware and software interferes with
high speed communications, and what can be done about it. A NEC
UltraLite VERSA with 8 MB of memory contains about 70 million
transistors and costs upwards of $5000. Unfortunately this machine
lacks the hundred transistors necessary to buffer input on its
built-in serial port. This port is built in, so replacing it with
a better UART ship is out of the question. In normal operation
interrupt latency caused by the NEC's device drivers and DOS cause
errors at 38400 bps and above.

Setting the zmodem k parameter to 50 or 100 reduced overruns by
stopping transmission briefly before disk writes.

The best operation was obtained by hitting the F5 key while DOS 6
loads to bypass all device drivers and TSR programs. Operating
this way there were no data overruns (LSR 02 errors) at 38400 bps.
Operation at 115200 bps was possible by setting a large I/O buffer
and using the zmodem k numeric parameter. I was able to download
AM.DAT (a 15762427 byte FCC database of North American AM broadcast
stations provided on the "Ham Call" CDROM) with 3471 cps throughput
using ZMODEM compression. While nowhere near as compressible as
Columbia University's Kermit News compressible benchmark file, this
highly compressible file provides a stress test for compressed
transfers because of the resulting heavy disk I/O.


08 Framing Error generally caused by line noise or an incorrect
transmission speed ("baud rate") or format (number of bits). Also
caused by some cheap internal modems. Most protocols require 8
bits no parity (-8n) for proper operation. This is set
automatically by Omen Technology programs, but other programs may
not be so smart.


10 Break Interrupt generally caused by line noise or an incorrect
transmission speed ("baud rate") or format (number of bits). Also
caused by some cheap internal modems.


18 Framing Error and Break Interrupt (see above) in combination.






Chapter 15 Pg 44 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


This error may also be caused by defective 8250 UART chips. Some
internal modem cards have slow 8250 chips that do not operate
properly with computers faster than 4.77 mHz. Replacing the 8250
with a NS16550AN is recommended. Please refer to the "Brain
Damaged UARTS" subchapter for details.

Please refer to the In Case of Difficulty chapter of this document for
solutions.


15.6 TIMEOUT

Indicates the other program is not responding or the phone line has
disconnected. If this message appears at the start of a transfer, you
may be using the wrong speed or the wrong port.


Less commonly encountered GSZ error messages are explained in the
Professional-YAM manual.


15.7 No Carrier Detect

If you see a No Carrier Detect message, and you haven't lost the
connection, you should fix your modem cable or modem settings to allow
proper operation of the Carrier Detect signal (CD).

A poorer alternative is to give the d command: gsz port 1 speed 2400 d
t

Selecting the wrong port can provoke this message.

15.8 Port %d (%X) defective

When GSZ selects a serial port, it performs a quick hardware check to
verify the presence and minimal functionality of the 8250 family UART.
This message usually means a nonexistent port has been selected.

Reports have been received of functional but nonstandard UART chips
triggering this message.


15.9 COMMAND NOT FOUND

If you see this message, make sure GSZ is in the DOS PATH. Sometimes
this error is caused by having too many environment variable strings.










Chapter 15 Pg 45 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


15.10 Out of Environment

means there is not enough room in the program environment to accept more
data.

DOS prints this message when it cannot allocate more memory to
accommodate a "set" command, such as "set dirrx=c:/downloads/".

Try moving the "set" commands to the batch file that calls your comms
program, or to your AUTOEXEC.BAT file.

To increase environment, use the /E switch. The default is 160 bytes.

An example for your CONFIG.SIS file: SHELL=C:COMMAND.COM/E:256

NOTE: Large environments may cause GSZ.COM to lockup. This is less of a
problem with GSZ.EXE.







































Chapter 16 Pg 46 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


16. SLOW TRANSFERS

Some users report slower than expected file transfers even when few or
no errors are reported. Some possible causes are:

If "handshake slow" is used, throughput may suffer. Try one of the
other solutions to the "Line Status Register = 02" errors discussed
above. When using "handshake slow" it may be possible to increase the
modem's interface speed to 19200 bps or faster.

Bad phone lines will silently slow MNP modems, sometimes without any
error indications. If the modems disconnect fairly often you should
suspect marginal phone line conditions that are being hidden by MNP
error correction.

One of the programs may have set a parameter or option that acts to slow
the transfer under certain conditions.







































Chapter 17 Pg 47 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


17. IN CASE OF DIFFICULTY

17.1 LOCKUPS

17.1.1 Insufficient Memory
GSZ complains when it detects insufficient memory to operate. When
calling GSZ from another program, there may be ALMOST enough memory for
proper operation, but GSZ locks up during a transfer or the calling
program freezes after GSZ displays the "GSZ Finished" message.

Sometimes there is a message about insufficient memory, sometimes just a
lockup and no message. To verify this problem, call CHKDSK from within
your comms program (not from DOS!) by defining it as an external
protocol. If you use an interface program (Hotkeyz, Prodoor, etc.), you
must call CHKDSK from that program, as those programs also reduce the
memory available to GSZ.

CHKDSK should report at least 64k free memory. If less memory is
reported, reduce the size of the COMMS program's capture buffer, or
reboot the system with fewer/smaller device drivers and TSR programs.
Calling GSZ directly from the comms program instead of from an interface
also saves memory.


17.1.2 Environment TOO BIG
A large environment may cause GSZ.COM to lockup. The size of the
environment (the amount of text you get when you give the DOS "set"
command) is subtracted from the data space available to 8086 C programs.
This can be a problem with GSZ.COM, whose 8086 tiny model limits code,
data, stack, and environment to 64 kb TOTAL. Use GSZ.EXE (compiled with
8086 small model) to alleviate this problem.


17.1.3 Bad COM Port Configuration
GSZ is fastidious about which interrupt vectors it takes over. Unlike
some programs, GSZ uses only the correct interrupt vector for its
interrupt service routine. (This allows multitasking.)

GSZ obtains and releases this vector with standard DOS function calls.
This allows multi line operation under DESQview and other multitasking
systems.

Incorrectly configured serial ports that work with programs that pig out
both IRQ3 and IRQ4 will lock up with GSZ. If GSZ locks up the machine
as soon as it tries to send or receive data, this is usually the fault.
Make sure the comm port is strapped correctly; COM1 uses IRQ4, COM2 uses
IRQ3. GSZ will lock up if the comm port is not properly set up.

In addition, GSZ will not work properly if two devices are connected to
the same IRQ line, even when some other programs (that don't use
interrupts as intensively) do work normally on the same machine. Make





Chapter 17 Pg 48 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


sure no other device uses the same IRQ as GSZ even if that device is not
active.

COM3 and above are not widely standardized. If you have problems with
COM3 or COM4, chances are your "COM3" is non standard.


17.1.4 LAN Manager Conflicts
Some Local Area Network (LAN) managers take over comm ports using code
that interferes with GSZ.

The following hint is from Tom Louvaris, LANtastic Sales/Support - New
York. Other LAN managers may require similar incantations to keep the
LAN manager from messing with GSZ's comm port.

Problem: When the lan is running, GSZ intermittently fails. GSZ starts
the transfer by displaying "Ready to send pathname". The receiving
system does noting. Eventually, GSZ exits with code 1, and no file is
sent.

To release one or more Com Ports with LANtastic 3.x, enter the
following...

Net Queue Halt \Sever-name Comn


Note: You must be logged on to "Server-name" with Queue privileges to





























Chapter 17 Pg 49 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


enable the operation of this command.

17.2 Incorrect Batch Files

Incorrect batch files are the number one source of problems using GSZ
for uploads and downloads. Bulletin board programs with convoluted
batch file mechanisms exacerbate the problem.

GSZ's command line echo was added to assist in correcting defective
batch files. You should see a display like:

Command line = 'rz '
or
Command line = 'port 2 speed 9600 sz foo.baz '

You may have to add a "pause" command at the end of the batch file to
allow GSZ's messages to be seen. Another possibility is to turn on the
printer with ^P before running GSZ, so GSZ's message can be saved on
paper.

In general, the Command line display should look like one of the
examples in this document or those displayed by GSZ itself. (The
Command line display does not include the name of the GSZ program
itself.)

Try running GSZ by itself, without any batch files or TSR programs,
calling it directly from DOS as described above.


17.3 Cheap Internal Modems

Numerous trouble reports have been received lately caused by cheap
internal modems causing errors on ZMODEM transfers but not XMODEM. A
similar problem was experienced in the mid 80's during beta testing of
some 2400 bps modems. Perhaps defective LSI chips left over from those
days were cloned or recovered from the trash bin.


17.4 Commands Entered in Upper Case

Most GSZ commands and options must be entered in lower case (small
letters, not big letters). Where the documentation or help screen
indicates "rz", you must use "rz" and not "RZ".


17.5 No Carrier Detect

If you see a No Carrier Detect message, and you haven't lost the
connection, you should fix your modem cable or modem settings to allow
proper operation of the Carrier Detect signal (CD).






Chapter 17 Pg 50 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


A poorer alternative is to give the d command: gsz port 1 speed 2400 d
t


17.6 DOS 3.x

DOS 3.x systems may need to have a "STACKS = 8,256" line in CONFIG.SYS
to prevent antisocial behavior. This is required on the NEC Multispeed,
or if certain TSR's are used.


17.7 Perstor Controllers

Several reports have been received indicating Perstor disk controllers
interfere with data communications. Perstor is reportedly working on a
fix.


17.8 IBM PS/2 Model 50Z

Early samples of this machine have a design error on the motherboard
that causes comms programs to lock up the machine. Replacing the
motherboard with a correctly functioning unit from current production
corrects the problem. The part number of the replacement PS2/50 Z
motherboard is 35F5928. (Information provided by John M. Choma
73047,3566) U.S. IBM stonewalled on this issue, but in December 1988
agreed to replace the defective motherboards under warranty.


17.9 Brain Damaged UARTS

Omen Technology has received reports of problems with buggy 8250 type
UART integrated circuits in Leading Edge modem boards, serial port
interfaces, and computers. The defective chip logic affects high
performance software. Replacing the buggy chip with a newer chip
(NS16550AFN) corrects the problem.

The UM82450 chip in the Zoom 2400HC also appears to cause problems.
Zoom Telephonics advises that this problem is limited to their old
model. The old model has an external volume control.

You can identify an old chip by inspecting the serial interface board
for 8250 or UM82450 type devices. A service technician or hardware
hacker can help if you are not familiar with reading chip numbers.

Dsz users can identify old chips with the following software command:

EXAMPLE: dsz port 1 speed 2400 p

The resulting value for the P numeric parameter should be 1. A value of
0 indicates a non-buffered chip or a chip with a defective buffer.





Chapter 17 Pg 51 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


ZCOMM and Professional-YAM users can look at the printout produced by
the s command; old UART chips register as TYP 0.

Some internal modems and PCMCIA cards use a firmware simulated UART that
is not detected as a buffered UART. Properly designed firmware UARTs
provide excellent buffering.

The National Semiconductor NS16550AFN is a pin compatible plug in
replacement for 8250 and 16450 serial chips. Omen Technology PCDOS
software enables the FIFO buffer in the NS16550AFN to prevents loss of
data from poorly written device drivers, TSR programs, etc.

We are also using the Goldstar GM82C550 chip with a 9025 date code.
This Goldstar chip is plug compatible with the National chips. No
problems have been discovered with this chip.

The NS16550AFN has better electrical characteristics than the older UART
chips. 386 and fast 286 machines should use the NS16550AFN for best
results. Omen Technology software has been written to allow time for
the older UART chips to operate. However, there is a limit to how much
the software can rearrange chip accesses without resorting to
performance robbing wait loops. Some other software is not as forgiving
of slow chips.

Fortunately the FIFO UART chip situation continues to improve. As of
this writing, the following plug compatible chips are known to work.

+ National Semiconductor NS16550AN and NS16550AFN, Goldstar GM82C550,
Startech 16550
Startech ST16C650CP This chip has 32 byte FIFO buffers and special logic
to support improved response time when using hardware flow control.
This chip may cause lockups when used in a Windows or Windows-95 DOS
Box.
********************
ERROR:input line 3281:LE:mismatched
******************** Texas Insturments TL16C550C This chip has special
logic to support improved response time when using hardware flow
control. This seems to reduce overruns when used in a Windows DOS Box
compared to regular FIFO devices.
********************
ERROR:input line 3287:LE:mismatched
******************** Current Western Digital WD16C550 chips do not
function properly at low speeds.

The Startech 16C552 contains two UARTS and a buffered parallel
interface.

If your UART chip is soldered in or otherwise not replaceable, you will
need a new plug-in board with a good UART chip. Byte Runner
Technologies 800-274-7897 offers a variety of boards and chips.






Chapter 17 Pg 52 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


Another is the KW-524E-1 Serial/Parallel/Game card, $30.90 from TSD
Systems, 800-331-9130 (FAX 407-331-8130). A board populated with two
FIFO UARTS is $41.85.

The Hayes ESP board comes with two serial ports with NS16550AFN devices.
The ESP definitions for COM3 and COM4 agree with the industry standard
definitions used by Omen Technology. All option switches on the ESP
board should be OFF except those used to select the port number (COMn).


The $99 "WinSport II" from Boffin LTD 612-894-0595 has two NS16550AFN
FIFO UARTS and also supports MobyBaud (18.432 MHz clock). This card

also supports higher IRQ numbers, freeing up the low IRQs for other
applications.

Software Electronics 503-640-1946 sells a $59 board with two FIFO UARTS
and a bidirectional enhanced parallel port.

The following information comes from a number of people:

"I have located a small dealer in New York who has the cards with or
without the 16550. I believe the price is around $50.00. The company
is RJK Consulting and the number is 718-968-9167. The gentleman to speak
to is a Mr. RJ Kulman. ... I got this information off the "Interlink"
BBS system." Fm: Nick Braak [TRICON] 75156,1254

Fry's - 415-770-FRYS. This is a Silicon Valley electronic department
store.

Jameco Electronics at 415-592-8097 800-538-5000 sells National
NS16550AFN chips mail order (credit card) in small quantities.
Unfortunately, we received a number of reports (none recently) that
their serial i/o card was supplied with the defective WD16C550 soldered
in, even when ordered with specific instructions to include 16550AFN
chips.

TSD Systems advertise a 2 serial/parallel/game card with one or two
NS16550-AFN chips. 800-331-9130(voice) 407-331-8130(fax)

Microprocessors Unlimited, 24000 South Peoria, Beggs, OK. (918) 267-
4961. The price for the chip is $13.50 plus shipping costs.

Consolidated Computers 4 Shoppers Lane Suite 121 Turnersville, NJ 08012
(609)751-9595(voice) (609)751-3843(bbs) (609)751-3840(fax)

Arrow Electronics at 800-932-7769 (516-467-1000).

Willies Computer Software Company: 800/835-4832.

N.B.: Current Western Digital WD16C550 chips do not function properly at
low speeds. This has been confirmed with samples received directly from





Chapter 17 Pg 53 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


Western Digital. WD is aware of this problem, but has not informed us
of a corrected chip.



17.9.1 Everex Internal Modems
Numerous reports have been received concerning difficulties with Everex
modem cards. Some of these cards contain buggy 8250 chips which are not
up to the demands of full duplex streaming protocols such as ZMODEM.
Replacing the buggy 8250 chip with NS16550AN chip corrects these
problems.


17.10 Weird Iron

A few machines, some with V20 CPUs, reportedly don't like DSZ.COM. We
have not been able to repeat this; TeleGodzilla (using a V20) runs
DSZ.COM without a hitch. Switching to DSZ.EXE has cleared up the
problems on other machines.


17.11 PKARC 3.6

It has been reported that PK36 grabs some interrupts and doesn't restore
them on exit in an attempt to prevent hacks of the program. Since
eliminating that particular version and cleaning up memory, high speed
transfers even with 8250 UARTS work properly again.

The problem with PK 3.6 appears to be most severe if a BBS operator has
doorware, etc that accesses the PK programs from a shell of some sort.
This info may be helpful to users who are having otherwise inexplicable
file transfer problems.

Phil Katz has written me that this problem has been corrected in
subsequent versions.


17.12 Will the real YMODEM please stand up?

Some XMODEM programs claiming to support YMODEM neither send nor accept
the YMODEM pathname block. 1024 byte XMODEM is XMODEM-1k, not the
YMODEM defined by Ward Christensen in 1985 when he invented the term
YMODEM. 1987 and later versions of YMODEM.DOC remind the reader of the
official YMODEM definition, which has not changed since YMODEM's coinage
in 1985.











Chapter 17 Pg 54 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


17.13 286 and 386 Extended Memory

Virtual memory disk caches and ramdisks using 80286 or 80386 extended
memory require a kludge hardware reset of the CPU chip to return to the
normal "real mode" after accessing extended memory. This interference
to the interrupt response time causes lost characters on comm ports, and
may be minimized by specifying shorter memory transfers.

Switching to a Goldstar GM82C550, National NS16550AN or NS16550AFN UART
chip helps tremendously, allowing transfers at 115200 bps instead of
9600 bps with a standard 8250. Please refer to the subchapter on "Brain
Damaged UARTs". The GSZ "handshake slow" command may also help.


17.14 Disk Caches

Cache programs often interfere with ZMODEM transfers. In one instance,
replacing Microsoft's SMARTDRV.SYS with Multisoft's SUPERPCK.EXE helped.
Norton NCACHE and and Multisoft PCQWIK have also caused errors.

Some cache programs can be turned on and off; try turning it off when
running GSZ.

The current SMARTCACHE can be used to advantage by using "handshake
slow" and the 'zmodem k" numeric parameter described in dszbg.doc.

Switching to a National NS16550AN or NS16550AFN UART chip helps
tremendously, allowing transfers at 115200 bps instead of 9600 bps with
a standard 8250. Please refer to the subchapter on "Brain Damaged
UARTs". The GSZ "handshake slow" command may also help.


























Chapter 18 Pg 55 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


18. ASSOCIATED DOCUMENTS

Consult the Professional-YAM, PowerCom, or ZCOMM manual chapter "OPTIONS
FOR FILE TRANSFERS" for descriptions of the file transfer options.
(ZCOMM is a full featured shareware communications program with
autodialing, autolearn scripting, and terminal emulation.) The "FILE
TRANSFER BASICS" chapter explains the relative merits of XMODEM, YMODEM,
ZMODEM, and other protocols and gives tips on their use. The "MAIN
COMMANDS" chapter describes the rb, rx, rc, rz, sb, and sz commands.
The "MODEM INTERFACING" and "FLOW CONTROL" chapters contain important
information on the use of buffered modems with GSZ.

Information on the ZMODEM Inter Application File Transfer Protocol is
available in Omen Technology's "ZMODEM DEVELOPER's COLLECTION" ($89.00).

Unix/Xenix C Source code for XMODEM, YMODEM, and ZMODEM transfers
to/from Omen Technology Products is included in RZSZ.ZOO.[1] This file
includes a Pro-YAM/ZCOMM script to upload a bootstrap file to a Unix
system, compile it, and (if the compilation is successful) upload the
rz/sz source files. (ZCOMM is a full featured shareware communications
program with autodialing, autolearn scripting, and terminal emulation.)


























__________

1. Technical support for rzsz is available on a paid consulting basis.






Chapter 19 Pg 56 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


19. FILES

Some of the batch files mentioned in this document are not included in
the archives. Those that are needed can be readily created with your
favorite editor.

DSZ.COM, DSZ.DOC, 2A-PIF.DVP, 2S-PIF.DVP, 2T-PIF.DVP, BBS_REG.TXT,
DS.BAT, FIX.BAT, MAILER, ZMODEMAD.BAT, ZMODEMD.BAT, ZMODEMDR.BAT, and
ZMODEMU.BAT constitute Omen Technology's DSZ.ZIP. These same files are
in DSZ.ZOO on the distribution diskette mailed to registered users.[1]

2S-PIF.DVP, 2A-PIF.DVP, DS.BAT, and 2T-PIF.DVP are used with Quarterdeck
Office Systems' DESQview multitasking executive for background
operation. Their use is described in a previous chapter of this
document.

DGSZ.ZOO is distributed to GSZ registrants. It contains GSZ.EXE and
GCOLORS.EXE in addition to the above.

ZCOMMDOC.ZIP (manual), ZCOMMEXE.ZIP (programs), ZCOMMHLP.ZIP (help
processor and database), make up the ZCOMM communications tools
shareware distribution. The ZCOMM files are available on finer bulletin
boards. (ZCOMM is a full featured shareware communications program with
autodialing, autolearn scripting, and terminal emulation.)

RZSZ.ZOO contains ZMODEM "C" source code for COMPLETE Unix/Xenix
programs licensed for use transferring files to/from licensed Omen
Technology products.[2]

RZSZ.TLB The ZMODEM rz/sz programs are available in native VMS flavors
with wild cards, record format support, etc.. Pre compiled VAX/VMS
files are contained in the RZSZ.TLB and RZSZAXP.TLB compressed text
libraries, available in the TeleGodzilla (503-621-3746) upgrade/vms
subdirectory, Compuserve VAXFORUM, GEnie, and other bulletin boards.
(RZSZAXP.TLB is for VMS on the Alpha machines.) The programs in RZSZ.TLB
are part of the extra value provided by Omen Technology communications
software.

DSZ.EXE compiled with the Xenix to DOS XC may give moderately higher
maximum throughput noticeable on slower machines. Sending from a faster


__________

1. DSZ.ZOO is supplied to registrants instead of DSZ.ZIP because not
all registrants have copies of unarchiving programs. The
registration disk includes a copy of BOOZ, a simple dearchiver for
ZOO files.

2. Technical support for rzsz is available on a paid consulting basis.






Chapter 19 Pg 57 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


machine to an 8 MHz IBM AT with 16550AFN, using 115200 bps and "sz -yZ
rttypix":

Program Throughput

DSZ.EXE 12735 cps
DSZ.COM 7164 cps

ProComm+2.0 5928 cps

(Compare these speeds to those listed on Page 159 of the April 30, 1991
issue of PC Magazine. Results are even better with the compressible
file used in the PC Magazine tests.)

DSZ.EXE supports ZMODEM over 7 bit paths (E and P options), and
specified control character quoting (-Q option). The DSZ.EXE
requires somewhat more memory than DSZ.COM. The maximum DSZ.EXE I/O
buffer size available with the B numeric parameter is 16384. DSZ.EXE is
available in DSZEXE.ZIP and DSZEXE.ZOO.

ZCOMM and Pro-YAM also run faster than DSZ.COM. (ZCOMM is a full
featured shareware communications program with autodialing, autolearn
scripting, and terminal emulation.)

DSZBG.ZOO contains DSZBG.DOC. Part of the GSZ registration disk, this
file provides background information on the ZCOMM/Pro-YAM commands
provided in DSZ and GSZ.

The ZOO archive format is a machine independent improvement on the PC-
DOS specific .ARC format. The ZOO format has been precisely defined, and
stable ZOO archivers/dearchivers are available on a wide variety of
systems.

BOOZ.EXE unpacks .ZOO archives. BOOZ.DOC describes BOOZ.EXE.






















Chapter 20 Pg 58 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


20. Other Omen Technology Products

20.1 Professional-YAM COMMS TOOLS

Omen Technology makes Professional-YAM, a comprehensive comms program
with unmatched power. (Professional-YAM is a full featured commercial
communications program with autodialing, autolearn scripting, and
terminal emulation.) Flavors are available for PC-DOS, Unix, Xenix, and
OS/2 Protected mode. Unix source code is available under license.


20.2 ZCOMM: Industrial Strength COMMS Shareware

ZCOMM is a full featured shareware version with a $40.00 basic
registration. Registered GSZ users upgrading to ZCOMM get a free
binder!


20.3 ZMODEM Developer's Collection

Omen Technology sells the "ZMODEM Developer's Collection" for $89.00.
This diskette includes the most recent public domain versions of
YMODEM.DOC, ZMODEM.DOC and the Unix/VMS rz/sz C source code for YMODEM
and ZMODEM. Porting to the intended application is the sole
responsibility of the purchaser. For many developers, this collection
affords a significant labor savings in obtaining these materials.






























Chapter 21 Pg 59 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


21. FAIR PLAY

Unlike snazzy menu interfaces, reliable high speed transfer protocols
take many hours of testing, often over expensive phone connections, to
develop. Two decades of communications experience and protocol testing
are distilled in GSZ.

GSZ is a user supported program developed and supported by Chuck
Forsberg, owner of Omen Technology. Countless hours of work and
expen$ive resources went to develop and support GSZ for the myriad
environments users use it in. The fact that most of the problems people
encounter with GSZ are caused by other software, hardware problems,
failure to read the supplied documentation, or pirating has not kept
users from seeking and getting help, even if it means calling the author
in the middle of his sleep.

Beyond this, the world of communications is constantly evolving, and it
requires a significant ongoing effort to keep GSZ and its documentation
up to date with the current state of the art. Individuals with little
knowledge of the dynamic nature of telecommunications (or hidden
agendas) have misrepresented the frequency of enhancements to GSZ as a
sign that GSZ is "unstable" and unworthy of "serious consideration". If
you think such sniping is fair play, you are more than welcome to use
one of the many other protocol programs available, each of which claim
to offer speed and reliability comparable to GSZ.

Non registered users are welcome to use GSZ for a reasonable evaluation
period. "Reasonable" means "until you've decided whether the program is
worth $30.00." It does not mean "until some competing program gets
around to adding ZMODEM or True Ymodem(TM)". Once you've evaluated GSZ,
ethical use of GSZ requires registering the copy.

GSZ is not and never has been Public Domain. Every version of GSZ has
included a Copyright Notice and a prohibition against sale or
modification. There is no usage counter or other Trojan Horse in GSZ,
but if you use this program, you have a moral and ethical obligation to
register it.

Paid registration enables t -8g, DIRRX, DSZOPT, OverThruster(TM),
YMODEM-g, and other advanced features that are present in GSZ.ZIP in
encrypted form. The registration package serializes and decodes all
past and future versions of GSZ.COM and GSZ.EXE. You can get a fully
featured upgrade of GSZ simply by downloading a newer version from
ftp.cs.pdx.edu, TeleGodzilla (503-621-3746), BIX, GEnie (IBM
Roundtable), CompuServe, and trusted bulletin boards.











Chapter 21 Pg 60 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


21.1 Sharing GSZ Files

You are welcome to share unmodified copies of GSZ.ZIP or GSZ.ZOO with
your friends and associates for their evaluation. This documentation
file and the MAILER file must be provided with all copies of GSZ except
by prior written permission from Omen Technology Inc. Because of piracy
problems, Omen Technology must INSIST that GSZ be distributed only as
part of the GSZ.ZIP file EXACTLY as provided by Omen Technology Inc, or
in an archive which displays a CRC value for GSZ.COM equal to that shown
in the Changes chapter. If GSZ.ZIP is repacked, no files may be added
to or removed from the archive.

If you see an improperly packed or otherwise modified GSZ archive or
parts thereof in a bulletin board, please ask the board's operator to
replace such files with GSZ.ZIP exactly as provided by Omen Technology
Inc. Flame them until they behave ethically.

Unmodified copies of Omen Technology shareware and demo files including
GSZ.ZIP, DSZ.ZIP and DSZBG.ZIP may be distributed by "shareware
distributors" provided 1) the files are clearly identified as
unregistered shareware, 2) the cost of the distribution is nominal.
Otherwise, no version of GSZ may be sold without the prior written
permission of Omen Technology Inc.

GSZ is not and never has been Copy Protected. "GSZ unprotect" files
have no function whatsoever except to aid and encourage the theft of
Omen Technology's Intellectual Property.

Distribution or use of programs or procedures that modify, patch,
disassemble, decompile, or otherwise reverse engineer GSZ without the
prior written permission by Omen Technology Inc is a bloody theft of
intellectual property and services and is a violation of Federal
Copyright Law. The same applies to debug scripts and documentation
written for the same purposes. These perform the same function as
pirate satellite and/or cable descramblers, to obtain benefit from
encrypted communications without proper payment. Piracy has been
investigated by the FBI and prosecuted under federal statutes.
Applicable law provides for damages and recovery of attorney's fees.
Omen Technology has received reports of serious problems caused by
unauthorized patches to GSZ, and cannot assume liability for the
performance of the resultant code. So far, none of the slime producing
such bilge have seen fit to sign their real name and address to their
cretinous attempts at ego gratification.

Distribution of GSZ in any medium without this documentation file is an
unauthorized modification to GSZ that deprives the rightful author of
registration revenues. That is a theft of intellectual property. Such
distribution damages the author by forcing the user and author to waste
time and phone bills scrounging for the documentation, and answering
questions that are fully covered in the documentation.






Chapter 21 Pg 61 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


If any version of GSZ is distributed with any other product, software or
hardware, the product documentation must clearly and prominently state
that the customer's continued use of GSZ requires registration directly
with Omen Technology or its duly authorized agent(s). When unregistered
copies of GSZ are distributed on disk, a contemporary copy of
ZCOMMDOC.ZIP should be included on the same disk.

Thank you for your support.

21.2 REGISTRATION


DSZ Upgrade!! Include your PAID REGISTRATION DSZ SNP card and take
$15.00 off the registration fee!! (The card must be mailed with the
order.) (Be sure to copy your DSZ SNP for safe keeping.) After a short
evaluation period, ethical users must register their copy of GSZ with a
check for $30.00 in U.S. funds sent to:

Omen Technology Inc.
P.O. Box 4681
Portland, OR 97208

The address on your check is sufficient, no need to fill out forms.

For VISA/MC Registrations, you can also:
Call VOICE: 503-621-3406

Or register online: 503-621-3746
Or FAX the INSTANT MAILER to: 503-621-3735

Don't bother scrounging for an envelope, just print the INSTANT MAILER
included in this archive!

Overseas registrations are sent out International Air Mail. Users,
especially those overseas, may choose to register their copy of GSZ for
$35.00 U.S. by providing their VISA or Mastercard card number with
expiration date and their name as it appears on their credit card.

Purchase orders for less than $150 must be prepaid. Omen Technology Inc
Federal TAX ID #: 930858776 Oregon TAX ID #: 536565
.ne 12

"Das Recht zur Benutzung von DSZ in Deutschland, Oesterreich und der
Schweiz erwerben Sie durch Bezahlung der Lizenzgebuehr von DM 57,00
(incl. Mwst) an RzK

Doris Koepke
Bitzenstr. 11
D-5464 Asbach

Tel. 02683-4547, FAX 49 2683 4537, Telex 86 3705 rzk d, CIS





Chapter 21 Pg 62 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


[70126,1660]. Sie erhalten dann von dort sowohl die neueste Version, als
auch Ihren individuellen Software-Key, mit dem Sie auch kuenftige
Shareware-Versionen "aufschliessen", also die in der Shareware Version
nicht zugnglichen Programmfunktionen nutzbar machen koennen, per Post.
Die Benutzung nicht registrierter Versionen stellt einen Verstoss
geltenden Rechts dar und wird strafrechtlich verfolgt."


*************************************************************************
The user registration package includes a printed serial number password
(SNP) card. The registration "care package" diskette contains the
latest versions of the GSZ programs, additional user documentation, and
the installation program which uses your personal SNP to enable advanced
features and bypass the opening advertisement.

The registration package unlocks the extra value in all past and future
versions of GSZ.COM and GSZ.EXE.
*************************************************************************

The unique serial number on the registration card is registered to the
user, and is acceptable proof of registration to corporate auditors.

The putsnp program inserts your unique DSZ Serial Number Password (SNP)
into you copy of DSZ with the following command:
putsnp dsz.com
Putsnp prompts for your SNP and asks appropriate questions before
inserting the SNP to enable the extra value in DSZ.

GSZ is serialized with the GCOLORS program described above.

Some TSR programs and device deivers interfere with putsnp. If you have
a lockup running putsnp, run it without any device drivers or TSR
programs (boot a plain DOS from floppy disk).

Your disk directory entry for GSZ will show the date and time you
serialized your copy of GSZ. This does not affect the revision date GSZ
announces when GSZ is run.


The only legitimate way to disable the opening advertisement in GSZ is
to insert an authorized serial number and activation key obtained from
Omen Technology into GSZ with the gcolors program. Any other
suppression or modification of the opening screen is an illegal,
unethical theft of services. Omen Technology has received reports of
serious problems caused by unauthorized patches to GSZ, and cannot
assume liability for the performance of the resultant code.

Piracy is stealing.








Chapter 21 Pg 63 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


21.3 Files on Registration Disk

The following files are currently included on the Registration Disk sent
to paid registrants.

BOOZ.EXE Program to unpack .ZOO archives. BOOZ.DOC describes
BOOZ.EXE.


DSZEXE.ZOO Contains DSZ.EXE.

To dearchive with booz: booz x dszexe

Type "booz" without arguments to see the help message.



DSZ.ZOO Contains DSZ.COM, DSZ.DOC, DESQview description files.

To dearchive with booz: booz x dsz


DGSZ.ZOO Contains GSZ, DSZ, GSZ.DOC, and DESQview description
files.

To dearchive with booz: booz x dsz

RZSZ.ZOO contains ZMODEM "C" source code for COMPLETE
Unix/Xenix programs licensed for use transferring files
to/from licensed Omen Technology products.[1]

To dearchive RZSZ with booz: booz x rzsz


PUTSNP.EXE Installs your unique registered serial number to enable
the extra value in DSZ. (GCOLORS is used for GSZ.)


DSZBG.DOC (in DSZBG.ZOO) Background information for GSZ and DSZ,
consisting of relevant parts of the ZCOMM User's Manual.

To dearchive with booz: booz x dszbg





__________

1. Technical support for rzsz is available on a paid consulting basis.






Chapter 21 Pg 64 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


21.4 Bulletin Board Registration

Note to the wise BBS operator: be sure you understand the GSZ restrict
command and how to use it.

Use and/or copying of GSZ by bulletin board sysops and/or systems is
allowed according to the following conditions:

I agree to feature the ZCOMM files (ZCOMMEXE.ZIP, ZCOMMDOC.ZIP,
ZCOMMHLP.ZIP) for downloading, and to announce the availability and
features of ZCOMM in any bulletins, help displays, or other displays
that mention communications programs. It is my responsibility to
maintain reasonably current versions of the ZCOMM files on the BBS shown
above.

I understand that I am welcome to use GSZ on my bulletin board(s) from
the time I sign and mail this document as long as I abide by the
conditions above, including featuring the above mentioned ZCOMM files.

I shall distribute GSZ.COM only as part of the GSZ.ZIP EXACTLY as
provided by Omen Technology Inc, or "zipped" without any file additions,
deletions, or modifications. If I distribute GSZEXE.ZOO, I shall also
maintain GSZ.ZIP in the same directory since GSZEXE.ZOO references files
in GSZ.ZIP.

If I see a modified GSZ archive or parts thereof in a file or collection
of files (e.g., archive) on a bulletin board, I shall replace such files
or archive members with the contents of GSZ.ZIP exactly as provided by
Omen Technology Inc. I shall report instances of noncompliance to Omen
Technology.

I shall not allow any version of gsz to be sold, modified, patched,
hacked, disassembled, decompiled, or otherwise reverse engineered
without the prior written permission of Omen Technology Inc.

I understand that GSZ is not and never has been Copy Protected. I fully
understand that "GSZ unprotect" files have no function whatsoever except
to aid and encourage the theft of Omen Technology's Intellectual
Property.

(For this BBS registration, a multi node bulletin board operating from a
single, common file system counts as one machine.)

The purpose of bulletin board registrations is to support and promote
ZCOMM and Professional-YAM by popularizing the ZMODEM protocol and
featuring the ZCOMM shareware files available for downloading.

BBS registrations must be submitted on the bbs_reg form with signature
and date, and must accompany a new paid GSZ or ZCOMM registration. The
paid registration that must accompany your BBS registration can be one
submitted by one of your board's users. Most boards have many





Chapter 21 Pg 65 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


unregistered GSZ users, so getting one of them to register their GSZ
should pose no difficulty. Since the paid registration may be from one
of your board's users, you can get your BBS registered for free by
getting one of your users to register his/her GSZ at the same time.




















































Chapter 21 Pg 66 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


22. CHANGES

Be sure to save your serial number/password (SNP) card and the putsnp
program you received from Omen Technology to use with future versions of
DSZ you may download! (Use GCOLORS to serialize GSZ.)

Current GSZ and DSZ versions are maintained on EXEC-PC BBS, BIX, GEnie
(IBM Roundtable), CompuServe (IBMCOM and CONSULT SIGs) as well as Omen's
TeleGodzilla (503-621-3746).

DSZ is a popular program which has been the object of virus attacks.
Pirated/hacked versions of DSZ have cost users and DSZ's developer
thousands of dollars in lost time and other expenses, in addition to
injuring of Omen Technology's reputation.

Virus and Trojan code hidden in hacked/pirated copies of DSZ and
programs claiming to "register DSZ" have caused loss of data.




-rw-rw-r-- 1 caf omen 33040 Jun 7 01:43 gcolors.exe
-rw-rw-r-- 1 caf omen 72352 Jun 7 01:43 gsz.exe
PKZIP -vt 32 bit CRC: 0E12A26F 72352 gsz.exe
PKZIP -vt 32 bit CRC: 5AE73B7E 33040 gcolors.exe


Your copy of GSZ should show the same CRC values. ZIP uses a 32 bit CRC
compatible with the Professional-YAM and ZCOMM "crc" command.
pkzip -vt gsz
The following Pro-YAM/ZCOMM command gives the 32 bit CRC for GSZ.COM:

EXAMPLE: >>>c: crc gsz.com


If your copy shows a different CRC or file length, insist on a
legitimate copy and report the source of the bogus/pirated copy to Omen
Technology Inc. Omen Technology has received reports of serious
problems caused by unauthorized patches to DSZ, and cannot assume
liability for the performance of the resultant code.


Good news for tired frog stompers! The ZMODEM rz/sz programs are
available in native VMS flavors with wild cards, record format support,
etc.. Pre compiled VAX/VMS files are contained in the RZSZ.TLB
compressed text library, available in the TeleGodzilla (503-621-3746)
upgrade/vms subdirectory, Compuserve VAXFORUM, GEnie, and other bulletin
boards. FTP access at ftp.cs.pdx.edu pub/zmodem/rzsz.tlb and Simtel20
mirrors. (Get RZSZAXP.TLB for Alpha VMS systems.)

The DSZ and GSZ "t" command uses the DOS console driver for terminal





Chapter 22 Pg 67 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


emulation. Standard ANSI.SYS is limited to a small subset of ANSI
escape sequences; NANSI.SYS, FANSI-Console and other replacement console
drivers provide faster screen updates and better ANSI terminal
emulation.

DESQview users: make sure "Separate Shift State" is set to "N". (Tnx to
Tim Trott for this info.)

Jun 7 1995: Added support for the Texas Insturments TL16C550C ACE with
AUTO-FLOW control. This chip is identified as type 4. GSZ displays
were optimized.
-h no longer spazzes.

Sep 18 1994: Supports the Startech ST16C650 ACE with 32 byte FIFOs and
on chip hardware flow control support. This chip is identified as type
3.

July 17 1994: GSZ and DSZ now accept extended receiver defined character
escaping requests which can specify the all ones character FF to be
escaped.

April 26 1994: The ZMODEM k, K and J numeric parameters have been added
to help on machines with old style UARTS encountering LSR 02 serial inut
errors.

Feb 25 1994: The Windows multitasking added in the Jan 27 version has
been modified; it was overly generous. The subchapter on Windows
operation has been changed.

Feb 02 1994: Fixed anomalies with YMODEM-g and time display. Hardware
support was revised to accommodate a Hayes ESP board incompatibility
with the 16550 spec.

Jan 27 1994: Added the "G" command to send an XON character to the
modem. This is useful when calling gsz from MSKermit as MSKermit sends
an XOFF character to the modem. Multitasking on OS/2 and Windows has
been improved. Handshake slow is more aggressive in flushing disk
buffers.

Nov 29 1993: Rebuilt to correct zipfile authentication problems.
Detection of 7-bit and nontransparent paths improved.

Nov 27 1993: Serial I/O has been tuned for more efficient operation
with internal modems using firmware driven virtual UARTs.

May 29 1993: The portx command now works with IRQ's up to 15, and,
optionally, nonstandard baudrate clocks.
EXAMPLE: dsz portx 3e8,15 rz -m

Newer UART chips can use raw bit rate sources higher than the standard
1.8432 MHz. Some 386 and 486 machines support MobyBaud(TM) operation





Chapter 22 Pg 68 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


above 115200 bps.

To support a nonstandard bit rate source, multiply 5760 by the new raw
bit rate source frequency in MHz divided by 1.84320.
EXAMPLE: dsz portx 3e8,15,57600 sp 38400 rz -m
supports the 18.432 MHz clock option on the Boffin Electronics "WinSport
II" 2 port serial board.

May 3 1993: SlugBait should now work for XMODEM and YMODEM. Some
problems with file transfers over 7-bit paths were fixed (DSZ.EXE,
GSZ.EXE).

Nov 9 1992: Unwanted registration info message removed from registered
copies. Enhancements to accommodate non standard XMODEM programs.
Corrected spurious automatic recognition of hardware handshake
configuration.

May 3 1992: Recompiled to correct bad file size/CRC values in DSZ.DOC
and DSZNEW, pruned some unused code. No functional changes from April
27 vsn.

April 27 1992: The GSZWINDOW environment variable can be set to 1, 2 or
3 to leave the top 1, 2 or 3 lines unmolested. DSZ.EXE is compiled on a
newer compiler and now supports file sharing.

Bogus/hacked/infected files with early 1992 revision dates have been
reported.

Dec 13 1991: DSZ and GSZ automatically support Doorway 2.2 without extra
commands.

The RZ.BAT and SZ.BAT files are supplied for convenience. RZ.BAT allows
calling programs that emit an "rz" command to automatically start GSZ
from the DOS command prompt. SZ.BAT is a convenient command interface
that complements RZ.BAT. You may modify SZ.BAT and RZ.BAT with your
favorite options.

The GSZ file transfer display now shows a distinct color at the
locations where error retries occurred. This gives a visual impression
of the distribution of error retries.

Oct 15 1991: To accommodate other vendors' programs which do not
provide a convenient way to control crash recovery, the "restrict"
command security check is not performed if the destination file does not
exist.

Oct 8 1991: Some versions of putsnp were confused by a data pattern in
the Oct 7 dsz.com, misplacing the installed serial number. Oct 7 1991:
The "t" (talk) command now accepts -h and -H to enable local echo. Oct
1 1991: Fixed an interaction between FIFO uarts and YMODEM-g termination
after all files have been sent. Fixed problem of some options being





Chapter 22 Pg 69 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


ignored on XMODEM and YMODEM downloads. Fixed graphics display problem
involving more than 40 MB of files. Sep 4 1991: GCOLORS now saves the
color scheme in a separate file GCOLORS.T. Many small improvements in
the GSZ file xfer display. GCOLORS adds a "m" menu choice to remove
color from the color scheme.

A conflict between crash recovery and user specified short packets has
been corrected.

DSZ.EXE and GSZ now accept the "c" option to force incoming files to use
a changed file name when a file with the same name exists. DSZ.COM does
not support this. The receiving program must support this new ZMODEM
option or file disposition will be undefined.

Aug 7 1991: Serial I/O modifications have solved a Wedge-O-Matic(R)
problem with one hardware configuration (antique 2400 bps internal
modem). Hopefully this will solve similar non-replicatable problems for
other users.

A number of display fixes/enhancements to GSZ, including the addition of
the GSZWINDOW environment variable enabling BBS sysops to protect BBS
status lines at the bottom of the screen.


July 29 1991: Corrections to gcolors registration function.

July 28 1991: Some changes to GSZ and CGOLORS to improve human factors.

"GCOLORS -q" disables the flashing reminder of which field is being
modified. This was added to help users with certain visual impairments.

A few users have reported hung transfers wither certain hardware and/or
software configurations. We have not been able to replicate the
problem, but have added code that recovers from lost interrupts.

July 21 1991: Preview release of GSZ!!




















Chapter 23 Pg 70 GSZ Reference Rev Jun-7-95 Typeset 6-7-95


23. ACKNOWLEDGEMENTS

32 bit CRC code courtesy Gary S. Brown.

ZMODEM-90(TM), MobyTurbo(TM), The High Reliability Software(TM), Demand
Upgrade(TM), TurboLearn Script Writer(TM), Cybernetic Data Recovery(TM),
ZMODEM AutoDownload(TM), Intelligent Crash Recovery(TM), Error
Containment(TM), Full Time Capture(TM), True YMODEM(TM),
OverThruster(TM), Password Guardian(TM), CryptoScript(TM), and
TurboDial(TM) are Omen Technology trademarks.

PowerCom was trademarked in 1985 by POLYTRON Corporation, Hillsboro
Oregon.

True YMODEM(TM) is an Omen Technology Trademark signifying YMODEM
protocol support that meets the full YMODEM specification.

GSZ and this documentation are Copyright 1991 by Omen Technology Inc,
all rights reserved. GSZ is not and never has been Public Domain.
Every version of DSZ has included a Copyright Notice and a prohibition
against sale or modification. This prohibition applies to any theft of
the intellectual property and trade secrets contained in GSZ by
decompilation, disassembly, or any other form of reverse engineering
including but not limited to profiling, tracing, data analysis, or
monitoring the operation of GSZ.

Omen Technology copyright applies to its expression of the encoding and
compression ideas expressed as code and byte streams used in the
ZMODEM-90 enhancements.

GSZ is not and never has been Copy Protected. "GSZ unprotect" files
have no function whatsoever except to aid and encourage the theft of
Omen Technology's Intellectual Property.

Omen Technology Incorporated
The High Reliability Software

17505-V Northwest Sauvie Island Road
Portland Oregon 97231
Modem: 503-621-3746 Speed 1200,2400,V.32
FAX: 503-621-3735
CompuServe:70007,2304 GEnie:CAF BIX:cforsberg
















  3 Responses to “Category : Recently Uploaded Files
Archive   : GSZ0607.ZIP
Filename : GSZ.DOC

  1. Very nice! Thank you for this wonderful archive. I wonder why I found it only now. Long live the BBS file archives!

  2. This is so awesome! 😀 I’d be cool if you could download an entire archive of this at once, though.

  3. But one thing that puzzles me is the “mtswslnkmcjklsdlsbdmMICROSOFT” string. There is an article about it here. It is definitely worth a read: http://www.os2museum.com/wp/mtswslnk/