** Z-148 SWITCH SETTINGS
---------------------

CPU BOARD
---------
SW402
-----

SECTION SETTING DESCRIPTION
------- ------- -----------
8MDS ON 8 MHZ OPERATION DISABLED
OFF *8 MHZ OPERATION MAY BE ENABLED
THROUGH THE FRONT PANEL 8 MHZ
SWITCH. THIS SWITCH MUST BE OFF
FOR NORMAL USE

8087 OFF 8087 OPERATION IS ENABLED. THE CPU WILL
ATTEMPT TO USE THE OPTIONAL 8087. IF THE
8087 IS NOT INSTALLED, THE SYSTEM
WILL LOCK UP DURING THE SELF TESTS AND NO
MESSAGE WILL BE DISPLAYED ON THE SCREEN

ON *8087 OPERATION DISABLED.IF THERE IS NO 8087
IN THE COMPUTER, THIS SECTION MUST BE IN THE
ON POSITION

60HZ ON *NORMAL SETTING. THE VIDEO DISPLAY IS
REFRESHED AT A 60 HZ RATE
OFF THE DISPLAY IS REFRESHED AT 50 HZ

PRDS ON MEMORY PARITY CHECKING IS DISABLED. IF THE
MEMORY PARITY CHIPS ARE NOT INSTALLED ON THE
CPU BOARD, THIS SWITCH MUST BE ON, OR AN
ERROR WILL BE GENERATED DURING THE SELF
TESTS
OFF *MEMORY PARITY CHECKING IS ENABLED

HRMV ON *INITIALIZE THE VIDEO SECTION OF THE I/O
BOARD ON POWER UP
OFF INITIALIZE THE VIDEO ADDRESSES FOR A HIGH
RESOLUTION MONOCHROME CARD. IF SUCH A CARD
IS NOT INSTALLED AND THE SWITCH IS OFF,
NOTHING WILL BE DISPLAYED ON THE SCREEN

1,2,3,4,5 LENGTH OF THE WAIT STATE, MEASURED IN
CLOCK PULSES, WHEN I/O OPERATIONS ARE
OCCURING

POSITION
--------
1 2 3 4 5
- - - - -
ON OFF OFF OFF OFF ONE WAIT STATE-FOR 5 MHZ OPERATION ONLY OFF
ON OFF OFF OFF OFF TWO WAIT STATES
OFF OFF ON OFF OFF THREE WAIT STATES- 5 OR 8 MHZ OPERATION
OFF OFF OFF ON OFF FOUR WAIT STATES
OFF OFF OFF OFF ON FIVE WAIT STATES

NOTE: ONLY ONE SWITCH POSITION SHOULD BE ON AT ANY TIME

SW403
-----

SECTION SETTING DESCRIPTION
------- ------- -----------
FLIN ON NO FLOPPY DRIVES INSTALLED; CPU WILL LOOK
FOR A NETWORKING CARD
OFF *FLOPPY DISK DRIVES INSTALLED

2/1D ON *ONE FLOPPY DISK DRIVE INSTALLED AS REPORTED
BY SOFTWARE
OFF TWO FLOPPY DISK DRIVES INSTALLED AS
REPORTED BY SOFTWARE

BTFL AND BTWC CONTROLS AUTOBOOT

BTFL BTWC
ON OFF AUTOBOOT FROM WINCHESTER
ON ON DO NOT USE
OFF ON *AUTOBOOT FROM FLOPPY
OFF OFF MANUAL BOOT

M1 AND M2 ESTABLISHES MEMORY DEVICES USED

POSITIONS DEVICE TYPE MAXIMUM MEMORY
--------- ------------
M1 M2 BANK0 BANK1 BANK2 RECOGNIZED
-- -- ----- ----- ----- ----------
ON ON 64K 64K 64K 192K
ON OFF 256K 64K 64K 384K
OFF ON 256K 256K 64K 576K
OFF OFF 256K 256K 256K 640K

AMOUNT OF MEMORY INSTALLED
--------------------------

64K,128K,256K,512K ESTABLISHES AMOUNT OF MEMORY INSTALLED

POSITIONS
---------
64K 128K 256K 512K
--- ---- ---- ----
ON ON ON ON 64K
OFF ON ON ON 128K
ON OFF ON ON 192K
OFF OFF ON ON 256K
ON ON OFF ON 320K
OFF ON OFF ON 384K
ON OFF OFF ON 448K
OFF OFF OFF ON 512K
ON ON ON OFF 576K
OFF ON ON OFF 640K

I/O BOARD
---------

JUMPER DESCRIPTION
------ -----------
J201 *WIRED TO ENABLE INTERRUPT REQUEST 7 (IRQ7) FOR
THE PARALLEL PORT. THIS INTERRUPT CAUSES THE CPU TO
RECOGNIZE AND SERVICE A REQUEST MADE BY THE PARALLEL
DEVICE

J202 ENABLES COM1 OR COM2(THE SERIAL PORT). EITHER IRQ4 (COM1)
OR IRQ3 (COM2) CAN BE CONFIGURED BY THE PLACEMENT OF THIS
JUMPER. TO SELECT COM1 INSTALL A JUMPER AT PINS *2 AND 3;
TO SELECT COM2 INSTALL A JUMPER AT PINS 1 AND 2. IT IS SET
FOR COM1 AT THE FACTORY

J203 USED TO DETERMINE THE LIGHT PIN POLARITY. NOT SUPPORTED BY
ZDS- *NO JUMPER IS INSTALLED AT THE FACTORY. SETTINGS- FOR
POSITIVE PULSE, INSTALL A WIRE JUMPER BETWEEN PINS 1 AND
2; FOR NEGATIVE GOING PULSE, INSTALL A WIRE BETWEEN PINS 2
AND 3

J204 USED TO ESTABLISH THE VERTICAL/COMPOSITE SYNC POLARITY FOR
AN EXTERNAL MONITOR. FOR *POSITIVE SYNC POLARITY, INSTALL
A JUMPER BETWEEN PINS 1 AND 2; FOR A NEGATIVE SYNC,
INSTALL A JUMPER BETWEEN PINS 2 AND 3

J205 ESTABLISHES THE HORIZONTAL SYNC POLARITY FOR AN EXTERNAL
MONITOR. FOR *POSITIVE SYNC, INSTALL A JUMPER BETWEEN PINS
1 AND; FOR NEGATIVE SYNC, INSTALL A JUMPER BETWEEN PINS 2
AND 3

J206 USED TO SELECT EITHER A VERTICAL-ONLY OR COMPOSITE
(VERTICAL AND HORIZONTAL) SYNC SIGNAL FOR THE EXTERNAL AND
INTERNAL MONITORS. A CIRCUIT BOARD FOIL SELECTS THE
VERTICAL SYNC SIGNAL. IF A COMPOSITE SYNC SIGNAL IS
REQUIRED, INSTALL A JUMPER BETWEEN PIN LOCATIONS 2 AND 3,
AND CUT THE FOIL BETWEEN PIN LOCATIONS 1 AND 2. THE
VERTICAL SYNC SIGNAL IS SELECTED BY A FOIL BETWEEN
LOCATIONS 1 AND 2. IF THE FOIL HAS BEEN CUT AND THE
VERTICAL SYNC SIGNAL IS REQUIRED, REPLACE THE CUT FOIL
WITH A WIRE JUMPER BETWEEN PIN LOCATIONS 1 AND 2

NOTE: JUMPER LOCATION J206 WORKS IN CONJUNCTION WITH THE
JUMPERS AT J204 AND J216. J206 ESTABLISHES WHETHER THE
SIGNAL WILL BE THE VERTICAL-ONLY OR COMPOSITE SYNC. J204
SELECTS THE POLARITY OF THE EXTERNAL MONITOR AND J216
SELECTS THE POLARITY OF THE INTERNAL MONITOR. INDIVIDUAL
SYNC SELECTION FOR THE EXTERNAL AND INTERNAL MONITORS
CANNOT BE MADE; THEY ARE TIED TOGETHER THROUGH THIS JUMPER

J207 SELECTS THE SOURCE OF THE VERTICAL SYNC SIGNAL. FOR OUTPUT
FROM GATE ARRAY U211, INSTALL A JUMPER BETWEEN PIN
LOCATIONS 2 AND 2; FOR OUTPUT FROM PIN 5 OF U259, INSTALL
A JUMPER BETWEEN PIN LOCATIONS *1 AND 2

J208 NO JUMPER INSTALLED; NOT USED IN FUNCTIONAL UNITS. ITS
SOLE PURPOSE IS TO AID IN MANUFACTURING THE WIRE BOARD

J209 THIS JUMPER LOCATION ENABLES OR DISABLES THE LIGHT PEN
STROBE SIGNAL. IT IS WIRED BETWEEN PIN LOCATIONS 1 AND 2
TO ENABLE THE LIGHT PEN STROBE SIGNAL FROM
PIN 3 OF THE CRT CONTROLLER. TO DISABLE THE STROBE SIGNAL,
INSTALL A JUMPER BETWEEN PIN LOCATIONS 2 AND 3

J212 USED TO SELECT THE HORIZONTAL SYNC SIGNAL SOURCE. FOR
OUTPUT FROM GATE ARRAY U211, INSTALL A JUMPER BETWEEN PIN
LOCATIONS *1 AND 2; FOR OUTPUT FROM PIN 13 OF U259,
INSTALL A JUMPER BETWEEN PIN LOCATIONS 2 AND 3

J214 USED TO INCREASE THE PULSE WIDTH OF THE COLUMN ADDRESS
STROBE SIGNAL FROM PIN 19 OF THE GATE ARRAY.
*NO JUMPER IS INSTALLED, SO THE FALLING EDGE OF THE CAS
SIGNAL OCCURS WHEN IT SHOULD, MAKING SURE THE ROW ADDRESS
STROBE PULSES HAVE ADEQUATE TIME TO REFRESH THE DATA
WITHIN THE RAM BANKS

J215 USED TO SELECT THE POLARITY OF THE INTERNAL MONITOR'S
HORIZONTAL SYNC SIGNAL. FOR A POSITIVE HORIZONTAL SYNC
SIGNAL , INSTALL A JUMPER BETWEEN PINS 2 AND 3;
FOR A NEGATIVE SYNC SIGNAL, INSTALL A JUMPER BETWEEN PINS
1 AND 2 (MARKED WITH A "+" ON THE BOARD)

J216 USED TO SELECT THE POLARITY OF THE INTERNAL MONITOR'S
VERTICAL SYNC SIGNAL. FOR A POSITIVE SYNC SIGNAL, INSTALL
A JUMPER BETWEEN PINS 1 AND 2 (MARKED WITH A "+" ON THE
BOARD); FOR A NEGATIVE SYNC SIGNAL, INSTALL A JUMPER
BETWEEN PINS 2 AND 3


  3 Responses to “Category : System Diagnostics for your computer
Archive   : JUMPERS.ZIP
Filename : Z148

  1. Very nice! Thank you for this wonderful archive. I wonder why I found it only now. Long live the BBS file archives!

  2. This is so awesome! 😀 I’d be cool if you could download an entire archive of this at once, though.

  3. But one thing that puzzles me is the “mtswslnkmcjklsdlsbdmMICROSOFT” string. There is an article about it here. It is definitely worth a read: http://www.os2museum.com/wp/mtswslnk/